EXTERNAL SECTION
1.2
Replacing the Filter Cover
Assembly & Suction Filter/A
A. Periodically replaced parts/cycle
• Suction filter/A: Every 120,000 copies (7145)
• Suction filter/A: Every 100,000 copies (7235/
7228/7222)
• Filter cover assembly: Every 120,000 copies
(7145)
• Filter cover assembly: Every 100,000 copies
(7235/7228/7222)
B. Procedure
1. Remove the screw [1], then remove the filter
cover assembly [2].
2. Remove the suction filter /A [3].
3. Reinstall the above parts following the removal
steps in reverse.
Note:
• When installing the suction filter/A, be sure to
install it so that the white filter face is turned to the
inside of the main body.
Note:
• When an elevator tray unit is fitted, perform the
following to access the filter section.
• While pressing [1], lift up [2], and pull out the ele-
vator tray unit and the horizontal conveyance unit.
Do not remove the finisher.
To remove the finisher, see [III. DISASSEMBLY/
ASSEMBLY] of the finisher section.