ALL TYPES
11) Evaporator control valve.
- Make : NECAM.
- Typt : MEGA.
ESSENTIAL :
Before checking and setting the pressure, it is essential that you
read through and follow closely BROCHURE : BRE 0332.
Setting pressure - 1st stage.
- Pression de réglage vaporisateur-détendeur neuf :
•
1450 ± 50 mb.
- Pression de réglage vaporisateur-détendeur ayant déjto servi :
•
1400 ± 50 mb.
SPECIFICATIONS : PETROL/LPG DUAL FUEL SYSTEM
Setting pressure - 2nd stage.
- Setting pressure for a new evaporator control valve :
•
- 970 ± 10 mb
- Setting pressure for a used evaporator control valve :
•
- 960 ± 10 mb
12) Stepper motor
- Location : on the distributor.
13) Distributor.
- Location : on the evaporator control valve support.
14) Distributor electrovalve.
- Supply voltage : 12 volts.
- Resistance : 25 ohms.
142