Code
Description
166
Boot block check sum error
167
Clock not updating
168
Alert on LAN is not working
correctly.
175
System board error
176
The system cover has been
removed.
177
An inventory violation
occurred, such as a hardware
component was removed. This
error message is part of the
AssetCare and Asset ID
features of the computer.
184
The asset control antenna has
not been detected.
186
A system board or hardware
security error occurred.
187
The administrator password
and boot sequences have been
cleared.
102
IntelliStation User Guide
Action
1. Go to "Recovering from a
POST/BIOS update
failure" on page 119 and
follow the instructions to
run the POST/BIOS
recovery procedure.
2. If the problem persists,
have the computer
serviced.
Update the BIOS. See
"Updating system programs"
on page 34.
1. Go to Chapter 4, "Using
the Configuration/Setup
Utility program" on
page 43 and follow the
instructions to view the
configuration settings.
Verify that Alert on LAN
is enabled.
2. If Alert on LAN is enabled
and the problem persists,
have the computer
serviced.
Have the computer serviced.
Type the administrator
password. If the problem
persists, have the computer
serviced.
Type the administrator
password. If the problem
persists, have the computer
serviced.
Have the computer serviced.
Have the computer serviced.
Go to Chapter 4, "Using the
Configuration/Setup Utility
program" on page 43 for
instructions on setting an
administrator password and
the startup sequences.