"3: ITF": Minimum number of digits to be read for ITF
"4: STF": Minimum number of digits to be read for STF
"5: CODABAR": Minimum number of digits to be read for Codabar
Set minimum number of digits for the code to be scanned.
Press [ ] to decrease the setting value and [ ] to increase the setting value.
ITF entry range:
STF entry range:
Codabar entry range:
Setting a small number of digits increases the frequency of missing digits when scanning, or incorrectly
scanning depending on how barcodes are scanned, or the quality of barcodes. On the other hand, setting
a large number will decrease the possibility of such errors.
[5] Setting the communication environment
The communication environment settings following system initialization are follows.
Do not change these settings unless necessary.
Interface port
Communication protocol
Infrared interface port
TRANSMIT SPEED
PROTOCOL
74
2 - 20
(Default: 4)
1 - 20
(Default: 3)
3 - 20
(Default: 4)
Item
Optical (infrared interface port)
Ymodem protocol
Baud rate
115200 bps
SERIAL No.:
Protocol options
H. PARITY:
LINKUP TIME:
FIELD SPACE:
Default
ON (
Adds serial numbers to data
)
blocks.
ON (
)
Adds horizontal parity.
30
seconds
Ignore (
Trim
)