LED Lights and Power Supply

The LED lights (task lighting) are located inside the
control panel and are positioned to provide light
over each bezel when activated by the task light
switch.
LEDs Activated
Each light is an assembly that consists of an LED
and circuit board attached to a metal bracket
with a Phillips-head screw. Each bracket is placed
into a channel inside the top of the control panel.
Loosening the bracket set screw allows the
assembly to slide along the channel in order to be
removed or positioned directly over each bezel. The
circuit boards are wired in series to a light harness
and are replaced as one unit. If one light assembly
fails or a wiring connection is loose, all LEDs will be
out.
Note: When replacing task lighting, make sure each
light is centered over each bezel before installing the
control panel.
On range models, the LED power supply is located
above the surface burner manifold on the left side
of the control area. It is accessible by placing the
control panel in the service position. (See
.) The power supply is held in place with four
Panel
1/4-in. hex-head screws.
On rangetops, the LED power supply is located
below the left-side surface burners. It is accessible
by removing 2 Phillips-head screws that attach an
access plate located on the bottom of the rangetop.
The power supply is held in place with 4 Phillips-
head screws.
Power Supply Connections
J2
J3
J1 - Input (120 VAC)
J2 - LED Output
J3 - Light Switch