CAUTION: LAbEL ALL WIRES pRIOR TO DISCON-
NECTION WHEN SERVICING THE CONTROLS. WIR-
ING ERRORS CAN CAUSE IMpROpER AND DAN-
GEROUS OpERATION. ALWAYS VERIFY pROpER
OpERATION AFTER SERVICING THE AppLIANCE.
ATTENTION: AU MOMENT DE L'ENTRETIENDES
COMMANDES, ETIQUETEZ TOUS LES FILS AVANT
LE DEbRANCHEMENT. DES ERREURS DE CAbLAGE
pEUVENT ENTRAIUN FONCTIONNEMENT INAD-
EQUAT ET DAGEREUx.
Wall Thermostat Installation
Use Wall Thermostat #750003, or a 750 millivolt DC
two-wire circuit thermostat, to automatically control
your fireplace operation. The thermostat should be
placed in the same room as the heater, typically 5'
off the floor. Avoid drafty areas or any area that may
effect the accuracy of the thermostat.
The thermostat should be connected to the
insert using a minimum 16 gauge wire with a maxi-
mum length of 35 feet of wire.
1. Remove the Burner switch box to access the wire
harness. Connect one of the thermostat leads to
the orange pigtail lead extending from the wire
harness.
2. Connect the other thermostat lead to the TH
terminal on the valve. DO NOT DISCONNECT ANY
WIRES. See fig. 18.
At the wall thermostat, the two wires should
be connected to the two connection terminals on
the thermostat base plate per the manufacturer's
instructions.
For thermostatic function, place the rocker
switch in the T-STAT position. The pilot flame must
be lit.
������
������
��
���
������
Figure 18. Wiring Diagram for optional thermostat.
1
����������
�����
����� ��
��
��������
����������
���������
�������

Remote Control

The optional Jøtul Remote Control 129706 may be
installed in place of the factory-installed manual
Burner switch.
1. Remove the switch box from the valve compart-
ment. Remove the switch coverplate and discon-
nect the wires from the TH and TH/TP terminals
under the valve.
2. Install the Receiver switch/battery box assem-
bly supplied with the remote control onto the
front of the insert burner switch box. Install the
Reciever coverplate. See Appendix A, page 28 for
additional details.
3. Run the wires out the back of the switch box and
connect the leads to the TH and TH/TP terminals
on the valve. DO NOT DISCONNECT ANY WIRES
FROM THE VALVE.
4. Reinstall the switch box to the valve compart-
ment floor using the same nut previously re-
moved.

blower power Requirement

The blower is fully assembled and requires no adjust-
ment.
Run the 10 ft. power cord out forward from the fire-
place to the nearest grounded power outlet.
The blower must be electrically grounded in ac-
cordance with local codes or, in the absence of local
codes, with the current NFPA 70- National Electrical
Code or CSA C22.1-Canadian Code.
A three-prong (grounding) power supply plug
is included for protection against shock hazard
and should be plugged directly into a properly
grounded three-prong receptacle. DO NOT CUT
OR REMOVE THE GROUNDING pRONG FROM THE
pLUG.
ALWAYS DISCONNECT THE pOWER SUppLY bEFORE
SERVICING THE bLOWER.
��
��
����
��
���
������
��
������
��������
Figure 19. Blower Wiring Diagram
�����
������
��
��
��
��
��
������
��
��������