Gasket Inspection
It is important that the glass gasket be inspected at
least annually. Examine the ribbon gasket for signs of
deterioration and make sure the gasket has a posi-
tive seal. Replace the gasket if necessary. Refer to the
replacement parts list on page 27.
Glass panel or Gasket Removal
1. Use the Latch Release Tool to disengage the latches
from the glass frame. See fig 1, pg. 3.
2. Swing the bottom of the glass frame out and lift to
disengage it from the retaining lip at the top of the
firebox. Lay the assembly on a flat surface, protect-
ing the frame from scratches using a blanket or
towel.
3. The glass panel is held in place by four retainer
clips. Use a screwdriver to carefully pry these up off
the edge of the glass retaining walls. See fig. 35.
4. Remove the old gasket material.
Retainer Clips
Figure 35. Glass Retainer Clip locations.
Glass panel or Gasket Replacement
1. Wrap the new gasket material evenly around the
edge of the glass, peeling back the protective
strip to expose the adhesive as you go. Press the
adhesive side down onto the glass surface. Do
not stretch the gasket. See fig. 36.
2. Place the gasketed glass within the frame and
press each of the retainer clips back into place on
the retainer walls.
FOR REpLACEMENT, USE ONLY JØTUL
CERAMIC GLASS pANEL pART 17.
DO NOT USE ANY OTHER TYpE OF GLASS
WITH THIS AppLIANCE.
Figure 36. Gasket Replacement