Jøtul GI 350 DV Installation And Operation Instructions Manual

Direct vent gas fireplace insert
Hide thumbs Also See for GI 350 DV:

Advertisement

WARNING: If the information in
these instructions is not followed
exactly, a fire or explosion may
result causing property damage,
personal injury or death.
– Do not store or use gasoline or
other flammable vapors and
liquids in the vicinity of this or any
other appliance.
– WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical
switch; do not use any phone in
your building.
• Immediately call your gas supplier
from a neighbor's phone.
Follow the gas supplier's
instruction.
• If you cannot reach your gas
supplier, call the fire department.
– Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
– A carbon monoxide (CO) detector
shall be installed in the same
room as the appliance.
Installation and

Operation Instructions

AVERTISSEMENT: Assurez-vous de
bien suivreles instructions données
dans cette notice pour réduire
auninimum le risque d'incendie ou
d'explosion ou pour éviter tout
dommage matériel, toute blessure
ou la mort.
– Ne pas entreposer ni utiliser d'essence
ni d'autres vapeurs ou liquides
inflammables dans le voisinage de cet
appareil ou de tout autre appareil.
– QUE FAIRE SI VOUS SENTEZ UNE
ODEUR DE GAZ:
• Ne pas tenter d'allumer l'appareil.
• Ne touchez à aucum interrupteur.
Ne pas vous servir des téléphones
se trouvant dans le bâtiment où
vous trouvez.
• Appelez immédiatement votre
fournisseur de gaz depuis un
voisin. Suivez les instructions du
fournisseur.
• Si vou ne pouvez rejoindre le
fournisseur de gaz, appelez le
service des incendies.
– L'installatione l'entretien doivent
être assurés par un installateur ou un
service d'entretien qualifié ou par le
fournisseur de gaz.

Advertisement

Table of Contents
loading

Summary of Contents for Jøtul GI 350 DV

  • Page 1: Operation Instructions

    Installation and Operation Instructions AVERTISSEMENT: Assurez-vous de WARNING: If the information in bien suivreles instructions données these instructions is not followed dans cette notice pour réduire exactly, a fire or explosion may auninimum le risque d’incendie ou result causing property damage, d’explosion ou pour éviter tout personal injury or death.
  • Page 2 PLEASE READ THESE INSTRUCTIONS IN THEIR ENTIRETY AND MAKE THEM AVAILABLE TO ANYONE USING OR SERVICING THIS APPLIANCE. THIS PRODUCT MUST BE INSTALLED BY A LICENSED MASTER OR JOURNEYMAN PLUMBER OR GAS-FITTER WHEN INSTALLED IN THE COMMONWEALTH OF MASSACHUSETTS. We recommend that our gas products be installed and serviced by professionals who are certified in the U.S.
  • Page 3: Table Of Contents

    Table of Contents Installa Installa tion & Ser tion & Ser vice e e e e T T T T T ools ools ools Installa Installation & Ser Installa tion & Ser tion & Servic ools ools ..2 Unpacking the Fireplace Specifica Specifica tions...
  • Page 4 Fuel Conversion Kit - LP to NG ......#156445 Wisconsin. Wall Thermostat ..........#750003 In addition, the Jøtul GI 350 DV gas fireplace Remote Control ............. #129706 insert has been tested and listed as a direct vent gas fireplace heater and listed to ANSI Z21.88-1998 (NFPA Cast Iron Surrounds 54) and CSA 2.33-M98 for Canada.
  • Page 5: General Information

    Approved Vent Manufacturers gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a The Jøtul GI 350 DV fireplace insert is approved for certified kit is used. installation with direct vent chimney components Cetappareil peut être installé...
  • Page 6: Safety Information

    Clothing or other flammable materials should not be placed on or near the fireplace. The Universal GI 350 DV Gas Insert can be installed in Surveiller les enfants. Garder les vêtements, les most solid fuel burning fireplaces of either masonry meubles, l’essence ou autres liquides à...
  • Page 7: Fireplace Requirements

    Figure 2. Universal GI 350 DV dimensions. Minimum Fireplace Requirements The Universal GI 350 DV gas insert has been specifi- cally designed to be installed into a solid fuel burning factory built fireplace or a code approved solid fuel burning masonry fireplace with a tile flue liner.
  • Page 8: Hearth Protection

    18 1/4” 41 1/4” 35” Cast Iron Hearth Requirements Jøtul 18 1/4” Cast Iron Hearth protection in front of the GI 350 DV must be 20” 18” 16” 41 1/4” 37” w/ Plinth composed of any noncombustible material. It must...
  • Page 9: Vent Guidelines

    Scan 65i 43” 41 1/2” 40” 38 1/2” 37” w/ Mantel Heat Shield With 2” Riser 44” 42 1/2” 41” 39 1/2” 38” Scan 65i Use noncombustible without Mantel materials only. Heat Shield Table 2. GI 350 DV Mantel clearances.
  • Page 10: Masonry Fireplaces

    Chimney clean-outs must fit properly. Masonry Fireplace Vent Installation When installing the Universal GI 350 DV gas 1. 1. 1. 1. 1. Measure height of the chimney to fireplace open- insert into a masonry fireplace, the insert will be ing.
  • Page 11: Prefabricated Fireplaces

    Air Intake QUALIFIED OR LICENSED PLUMBER OR GAS FITTER. pipe does not connect directly to a Direct Vent The GI 350 DV gas insert is specifically designed Termination at the top of to be vented using a co-linear system. the chimney Installation includes a pair of 3”...
  • Page 12 The other 3” liner will be attached to the intake port on the back of the unit and will provide fresh air for combustion to the unit. This liner must extend a Listed Direct Vent minimum o minimum o minimum of 6 f f 6 f f 6 f f 6 ft t t t t .
  • Page 13: Vent Requirements

    Vent Connection Prefabricated Fireplace Vent Installation 1. 1. 1. 1. 1. Measure height of the chimney to fireplace The Vent Collar Plate, located on top of the cabinet, opening. Determine if both the intake and exhaust is removable to ease connection of the vent liners in will be extended to the top of the chimney.
  • Page 14: Gas Connection

    Connecting the Gas Supply Final Positioning 1. Blower Power Cord: Gas Supply Requirements Extend the blower power cord out forward of the fireplace, routing it to the nearest power source. ALL INSTALLATIONS MUST COMPLY WITH LOCAL CODE OR IN THE ABSENCE OF LOCAL CODE, MUST 2.
  • Page 15: Gas Pressure

    Soap Solution Leak Test • Mix a 50-50 solution of water and dish soap. The appliance must be isolated from the gas • Light appliance- see lighting instructions on page supply line by closing its individual manual gas shut- 23 of this manual or on the fireplace’s rating plate. off valve (gas cock) during any pressure testing of the gas supply piping system that is equal to or exceeds •...
  • Page 16: Fuel Conversion

    Fuel Conversion Conversion Kit Contents: #156444 - LP #156445 - NG The Jøtul GI 350 Fireplace is designed to for use with • 1 Regulator Tower labeled for Propane either Natural gas or Propane. It is shipped from the • 3 Regulator Tower Screws factory configured to use Natural gas.
  • Page 17 • Replace Pilot Hood by pushing it into the base. 5 5 5 5 5 ..R R R R R eplac eplac eplac eplace e e e e the Burner Assembly the Burner Assembly the Burner Assembly the Burner Assembly: : : : : Slide Slide Slide...
  • Page 18: Wall Thermostat

    Remote Control CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC- The optional Jøtul Remote Control 129706 may be TION WHEN SERVICING THE CONTROLS. WIRING installed in place of the factory-installed manual ERRORS CAN CAUSE IMPROPER AND DANGEROUS Burner switch. OPERATION. ALWAYS VERIFY PROPER OPERATION AFTER SERVICING THE APPLIANCE.
  • Page 19: Optional Wall Panel Kits

    Optional Brick Panel Kit Assembly C C C C C A A A A A U U U U U T T T T T ION: ION: ION: ION: T T T T T H H H H H ESE P ION: ESE P ESE P...
  • Page 20: Log Set Installation

    Log Set Assembly This is the heart of your fireplace. Much time and effort has been devoted to attaining a lively, realistic flame picture while simultaneously achieving efficient fuel combustion and effective heat output under a variety of installation condi- tions.
  • Page 21: System Check

    System Check Flame Appearance / Air Shutter 1. 1. 1. 1. 1. PU PUR R R R R GI GI GI GI GING NG T T T T T H H H H H E G E GA A A A A S LI S LI S LI S LI...
  • Page 22: Surround Assembly

    Surround Assembly Each of the surround assemblies and front facings is completely assembled at the factory. No further assembly is required. All assemblies utilize hooked brackets (fig. 30) that simply hang onto the inboard tabs on the fireplace cabinet as shown in fig. 10 on page 14.
  • Page 23: Burner Controls

    Figure 32. GI 350 DV Gas Valve and Regulator. 6. 6. 6. 6. 6. C C C C C A A A A A U U U U U T T T T T ION: ION:...
  • Page 24: Blower Controls

    Maintenance Figure 33. GI 350 DV Burner Control The GI 350 DV gas fireplace and its venting system BURNER should be inspected before use and at least annually Switch. by a qualified service technician. IMPORTANT: TSTAT ALWAYS TURN OFF THE GAS SUPPLY TO THE FIREPLACE AND UNPLUG THE FORCED AIR BLOWER BEFORE ANY SERVICE WORK IS PERFORMED ON THE FIREPLACE.
  • Page 25: Glass Replacement

    Gasket Inspection Glass Panel or Gasket Replacement 1. Wrap the new gasket material evenly around the It is important that the glass gasket be inspected at edge of the glass, peeling back the protective least annually. Examine the ribbon gasket for signs of deterioration and make sure the gasket has a strip to expose the adhesive as you go.
  • Page 26 Universal GI 350 lllustrated Part Breakdown Figure 37. Part Identification.
  • Page 27: Emen Emen Ts List Ts List

    Universal GI 350 DV Part List Description Part Number Description Part Number Screw, Pan Head 10-32 x 3/8 117911 Heat Shield, Right 222092 Valve Bracket 221385 Screw, #8 x 1/2” Blk 117917 Screw, #8 x 1/2” Blk 117917 Glass Frame Latch Release Tool...
  • Page 28: Appendix A: Remote Installation

    Appendix A Remote Control Installation The optional Jøtul Remote Control 129706 may be installed in place of the factory-installed manual burner switch. Follow this procedure: Receiver 1. Remove the Burner Switch Box from the valve compartment. Remove the switch coverplate and disconnect the wires from the TH and TH/TP terminals under the valve.
  • Page 30: Ser Ser

    Name of Technician ________________________ M M M M M ODEL NA ODEL NA ODEL NA ODEL NA ODEL NAME: ME: GI 350 DV Gas Fireplace Insert IAL N IAL N IAL NU U U U U MB ER:__________________________ ER:__________________________ Company Name ____________________________...
  • Page 31: Tions Tions

    LIGHTING INSTRUCTIONS FOR YOUR SAFETY, READ BEFORE LIGHTING. WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE. • If your gas supplier cannot be reached, call the A.
  • Page 32 This appliance must be installed in conformance with local and national building regulations. Before beginning the installation, it is important that the these instructions be carefully read and understood. Jøtul maintains a policy of continual product development. Consequently, products may differ in specification, color or type of accessories from those illustrated or described in various publications.

Table of Contents