CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-
TION WHEN SERVICING THE CONTROLS. WIRING
ERRORS CAN CAUSE IMPROPER AND DANGEROUS
OPERATION. ALWAYS VERIFY PROPER OPERATION
AFTER SERVICING THE APPLIANCE.
ATTENTION: AU MOMENT DE L'ENTRETIENDES
COMMANDES, ETIQUETEZ TOUS LES FILS AVANT LE
DEBRANCHEMENT. DES ERREURS DE CABLAGE
PEUVENT ENTRAIUN FONCTIONNEMENT
INADEQUAT ET DAGEREUX.
Wall Thermostat Installation
Use Wall Thermostat #750003, or a 750 millivolt DC
two-wire circuit thermostat, to automatically control
your fireplace operation. The thermostat should be
placed in the same room as the heater, typically 5'
off the floor. Avoid drafty areas or any area that may
effect the accuracy of the thermostat.
The thermostat should be connected to the
insert using a minimum 16 gauge wire with a
maximum length of 35 feet of wire.
1. Remove the Burner switch box to access the wire
harness. Connect one of the thermostat leads to
the orange pigtail lead extending from the wire
harness.
2. Connect the other thermostat lead to the TH
terminal on the valve. DO NOT DISCONNECT ANY
WIRES. See fig. 18.
At the wall thermostat, the two wires should be
connected to the two connection terminals on the
thermostat base plate per the manufacturer's
instructions.
For thermostatic function, place the rocker switch
in the T-STAT position. The pilot flame must be lit.
SWITCH
OR
T-Stat
V
Off
YE
On
Figure 18. Wiring Diagram for optional thermostat.
18
VALVE
THERMOPILE
TH TP TP
TH
OPTIONAL
THERMOSTAT

Remote Control

The optional Jøtul Remote Control 129706 may be
installed in place of the factory-installed manual
Burner switch.
1. Remove the switch box from the valve compart-
ment. Remove the switch coverplate and discon-
nect the wires from the TH and TH/TP terminals
under the valve.
2. Install the Receiver switch/battery box assembly
supplied with the remote control onto the front
of the insert burner switch box. Install the
Reciever coverplate. See Appendix A, page 28 for
additional details.
3. Run the wires out the back of the switch box and
connect the leads to the TH and TH/TP terminals
on the valve. DO NOT DISCONNECT ANY WIRES
FROM THE VALVE.
4. Reinstall the switch box to the valve compart-
ment floor using the same nut previously
removed.

Blower Power Requirement

The blower is fully assembled and requires no
adjustment.
Run the 10 ft. power cord out forward from the
fireplace to the nearest grounded power outlet.
The blower must be electrically grounded in
accordance with local codes or, in the absence of
local codes, with the current NFPA 70- National
Electrical Code or CSA C22.1-Canadian Code.
A three-prong (grounding) power supply plug is
included for protection against shock hazard and
should be plugged directly into a properly
grounded three-prong receptacle. DO NOT CUT OR
REMOVE THE GROUNDING PRONG FROM THE
PLUG.
ALWAYS DISCONNECT THE POWER SUPPLY BEFORE
SERVICING THE BLOWER.
POWER
SUPPLY
BK
BK
MANUAL
BK
OFF
AUTO
BU
SWITCH
SNAPSTAT
Figure 19. Blower Wiring Diagram
GN
W
GN
GY
BK
BK
BLOWER
BK
RHEOSTAT