Insert Clearances; Mantel Clearances; Hearth Requirements - Vermont Castings VC31LDVINTSC Installation And Operating Instructions Manual

Clean face direct vent fireplace insert
Table of Contents

Advertisement

VC31LDVI/VC31CDVI Gas Fireplace Insert

INseRt CleARANCes

No combustibles (ie: drapes, doors) may be within, or
swing within 36" of the front of the insert.
Side Wall
10" (254 mm)
Minimum
10" (254 mm)
Minimum
Figure 3 -

Mantel Clearances

mANtel CleARANCes
NOte: the combustible area above the facing must
not protrude more than 3/4" (19 mm) from the facing.
If it does, it is considered a mantel and must meet the
mantel requirements listed in this manual.
8
12"
(305 mm)
9"
(228 mm)
NOte: Side clearance
to combustibles is 10"
(254 mm) from opening
whether it is side wall or
FP2964
insert clearances
mantel legs.
12" (305 mm)
Maximum Depth
(305 mm)
3/4" (19 mm)
Maximum Depth
Combustible Facing
Fireplace Insert
Opening
Figure 4 -
Mantel Clearances
FP2964

heARth ReQuIRemeNts

The insert must be installed on a noncombustible hearth
extending a minimum of 10" (254 mm) from the fireplace
opening (local codes may require a larger hearth). The
hearth must also extend to both sides of the face.
Finish Wall
12" (305 mm)
4"
(101 mm)
12"
10"
(254 mm)
9"
(229 mm)
FP2965
mantel clearance
CleARANCes
3/4" (19 mm)
Noncombustible
Material Required
up to 9" Above
Fireplace Opening
FP2965
20304166