WARNINGS
If the information in this manual is not followed
exactly, a fire or explosion may result causing
property damage, personal injury or loss of
life.
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed
by a qualified installer, service agency or the
gas supplier.
This gas log set is to be installed only in a
solid-fuel burning fireplace with a working
flue constructed of noncombustible material.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future refer-
ence.
Approved to ANSI Z21.60 / CSA 2.26
Hearth & Home Technologies • VDY 24/18/30 Gas Log Heater Install/Owner's Manual • 32D1999 • Rev D • 05/19
"Duzy" Series
Vented Gas Log Set
Models:
VDY24/18, VDY30
Installation and
Operating Instructions
VDY24/18D2A
VDY24/18D4
VDY24/18D5
VDY30D3R
321999
VDY log cover

Advertisement

Table of Contents
loading

Summary of Contents for Vermont Castings Duzy Series

  • Page 1 Vented Gas Log Set Models: VDY24/18, VDY30 "Duzy" Series Installation and Operating Instructions WARNINGS If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of VDY24/18D2A life. –...
  • Page 2: Table Of Contents

    "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire CONTENTS Thank you and congratulations on your purchase of a Hearth & Home Technologies Log Set. PLEASE READ THE INSTALLATION AND OPERATION INSTRUCTIONS BEFORE USING THE APPLIANCE! IMPORTANT: Read all instructions and warnings carefully before starting installation.
  • Page 3: Important Safety Information

    "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire IMPORTANT SAFETY INFORMATION INSTALLER OWNER Please leave these instructions with the appliance. Please retain these instructions for future reference. • Any change to this gas log set or its Read these instructions carefully before controls can be dangerous.
  • Page 4: Getting Started

    "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire FEATURES & SPECIFICATIONS GAS PRESSURES MAKE SURE YOU HAVE RECEIVED ALL PARTS: Natural *Propane (LP) Check your packing list to verify that all listed parts have Inlet Minimum 6.0”...
  • Page 5: Minimum Hearth Dimensions

    PRODUCT SPECIFICATIONS "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire INSTALL AND OPERATE THE APPLIANCE MINIMUM HEARTH DIMENSIONS AS DIRECTED IN THIS MANUAL DAMPER STOP INSTALLATION A damper stop is provided with the unit. The damper stop must be installed as shown in Figure 2 to prevent full clo- sure of the fireplace damper blade and provide a minimum flue opening, per table below.
  • Page 6: Placement In A Fireplace With A Restrictive Barrier

    "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire IMPORTANT INFORMATION FOR THE IN- The log set STALLATION OF THIS GAS LOG SET should be placed against The following are guidelines for placing a gas log set or as near as Glass door possible to the...
  • Page 7: Installation

    INSTALLATION "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire GAS LINE CONNECTION PLACE AND SECURE APPLIANCE NOTICE: A qualified gas appliance installer must connect You must secure the gas log heater to the the heater to the gas supply. Consult all local codes. fireplace floor.
  • Page 8 "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire GAS LINE CONNECTION The heater gas inlet connection is 3/8" NPT at the reg- MILLIVOLT CONTROL ulator, inlet on the right side facing the gas log. If a left Figure 7 side connection is required, the connecting pipe may be The valve regulator controls the burner pressure which...
  • Page 9: Electrical Wiring - Millivolt

    ELECTRICAL WIRING "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. THTP Millivolt Valve Pilot FP2857...
  • Page 10: Log Placement

    "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire LOG PLACEMENT LOG PLACEMENT IMPORTANT: Remove logs, handling carefully by holding gently at each end. Gloves are recommended to prevent skin irritation from ceramic fibers. If skin becomes irritated, Right wash gently with soap and water.
  • Page 11: Vdy30D2A

    "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire LOG PLACEMENT Right Log #2 DUZY II VDY30D2A LOG PLACEMENT 1. Install the rear log (#1) on the two locating pins of base. Figure 14. Visually check to verify the log is securely placed on the pins and in contact with the grate.
  • Page 12: Vdy24/18D3R

    "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire LOG PLACEMENT Front Right DUZY III VDY24/18D3R LOG PLACEMENT Front Left Log #3 Log #2 1. Align pins on bottom of rear log #1 with pins on grate bar and place on grate.
  • Page 13: Vdy30D3R

    "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire LOG PLACEMENT DUZY III VDY30D3R LOG PLACEMENT Front Right Log #3 Front Left Log #2 1. Align pins on bottom of rear log #1 with pins on grate bar and place on grate.
  • Page 14: Vdy24/18D4

    "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire LOG PLACEMENT DUZY IV VDY24/18D4 LOG PLACEMENT Bottom Front Log #2 1. Place bottom front log (#2) on front of grate. Figure 29 2. Place back log (#1) on back of grate aligning two (2) pins on grate with holes in bottom of log.
  • Page 15 LOG PLACEMENT "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire 6. Rest right top log (#6) on center crossover log and front of grate. Figure 33 LG993 Left Crossover Log #5 Figure 32 Right Top Log #6 LG993 VDY2418D4 left cross log LG994...
  • Page 16: Vdy30D4

    "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire LOG PLACEMENT DUZY IV VDY30D4 LOG PLACEMENT Bottom Front Log #2 1. Place bottom front log (#2) on front of grate. Figure 34 2. Place back log (#1) on back of base aligning two (2) pins on base with holes in bottom of log.
  • Page 17 "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire LOG PLACEMENT Right Top Log #6 5. Place left top crossover log (#5) up against left top log. Figure 37 6. Rest right top log (#6) on center crossover log and front of grate.
  • Page 18: Vdy24/18D5

    "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire LOG PLACEMENT DUZY V LOG VDY24/18D5 Locator Pins 1. Place back log (#1) on back of base aligning two (2) pins on base with holes in bottom of log. Figures 39 and 40 Back Log #1 LG972 Figure 39...
  • Page 19 LOG PLACEMENT "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire Middle Right Middle Left Log #5 Log #4 4. Place one end of middle left log (#4) on bottom left log. Rest other end of middle left log (#4) behind middle right log.
  • Page 20: Vdy30D5

    "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire LOG PLACEMENT DUZY V VDY30D5 LOG PLACEMENT Locator Pins 1. Place back log (#1) on back of base aligning two (2) pins on base with holes in bottom of log. Figures 45 and 46 LG976 Back Log #1 Figure 45...
  • Page 21 LOG PLACEMENT "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire Middle Right Log #5 5. Place middle right log (#5) on top of bottom right log. Figure 49 LG1008 Figure 49 LG1008 Top Right VDY30D5 mid right log Log #6 Top Left Log #7...
  • Page 22: Glowing Ember Placement

    "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire FIREPLACE DRAFT TEST PLACEMENT OF THE GLOWING EMBERS Fireplace systems that do not draft properly can increase the amount of soot produced Cover the burner pan with glowing embers (rock wool) by normal operation of the log set and provided.
  • Page 23: Flame Appearance

    FLAME APPEARANCE "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire CHECKING BURNER FLAMES In normal operation at full rate after approximately 15 min- utes, the following flame appearance should be observed. Rear flame should be yellow and extend vertically.
  • Page 24: Operating Instructions

    "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire OPERATING INSTRUCTIONS SAFETY INSTRUCTION FOR MANUAL AND MILLIVOLT CONTROL WITH PILOT FOR YOUR SAFETY READ BEFORE LIGHTING A. This appliance is equipped with an ignition If you do not follow these instruction device which automatically lights the pilot.
  • Page 25: Millivolt Control Lighting Instructions

    "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire OPERATING INSTRUCTIONS MILLIVOLT CONTROL LIGHTING INSTRUCTIONS 1. STOP! Read the safety information label. 2. Make sure the manual shutoff valve is fully Wait 30 seconds before readjusting the open.
  • Page 26: Optional Remote Receiver (Millivolt)

    "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire REMOTE RECEIVER INSTALLATION Connect wires according to remote receiver instructions. The female terminals should be connected to factory DO NOT PLACE THE REMOTE IN THE attached male terminals which are located on right hand FIREPLACE IF ANY OF THE FOLLOWING side of the burner.
  • Page 27: Cleaning And Servicing

    CLEANING AND SERVICING "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire Turn off gas logs and allow to cool before cleaning. Disconnect electrical power if applicable before cleaning or servicing. Remove logs, handling carefully by holding gently at each DIAGRAM FOR LOCATION OF ITEMS DISCUSSED end.
  • Page 28: Troubleshooting

    "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire TROUBLESHOOTING Turn off appliance and allow to cool before NOTE: All troubleshooting items are listed in order of operation. cleaning. Only a qualified service person should service and repair the heater.
  • Page 29 TROUBLESHOOTING "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire Problem Possible Cause Solution 1. Press in control knob fully. Pilot lights, but flame goes 1. Control knob not fully pressed in. out when control knob is 2.
  • Page 30: Service Parts

    "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire SERVICE PARTS DUZY Service Parts Duzy 24/18” Hearth Kit Beginning Manufacturing Date: N/A Ending Manufacturing Date: Active VDY24/18NMP (Natural Gas Manual Control) - Ending Manufacturing Date: April 2019 VDY24/18PMP (Propane Manual Control) - Ending Manufacturing Date: April 2019 VDY24/18NVP (Natural Gas Millivolt Control) - Active VDY24/18PVP (Propane Millivolt Control) - Active...
  • Page 31 "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire SERVICE PARTS DUZY Service Parts Duzy 30” Hearth Kit Beginning Manufacturing Date: N/A Ending Manufacturing Date: Active VDY30NMP (Natural Gas Manual Control) - Ending Manufacturing Date: April 2019 VDY30NVP (Natural Gas Millivolt Control) - Active VDY30PMP (Propane Manual Control) - Ending Manufacturing Date: April 2019 VDY30PVP (Propane Millivolt Control) - Active...
  • Page 32 SERVICE PARTS "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire VDY24/18D2A Service Parts Duzy II 24”-18” Log Set Beginning Manufacturing Date: N/A Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor.
  • Page 33 SERVICE PARTS "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire VDY30D2A Service Parts Duzy II 30” Log Set Beginning Manufacturing Date: N/A Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor.
  • Page 34 "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire SERVICE PARTS VDY24/18D3R Service Parts Duzy III 24”-18” Log Set Beginning Manufacturing Date: N/A Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor.
  • Page 35 SERVICE PARTS "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire VDY30D3R Service Parts Duzy III 30” Log Set Beginning Manufacturing Date: N/A Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor.
  • Page 36 SERVICE PARTS "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire VDY24/18D5 Service Parts Duzy V 24”-18” Log Set Beginning Manufacturing Date: N/A Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor.
  • Page 37 SERVICE PARTS "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire VDY30D5 Service Parts Duzy V 30” Log Set Beginning Manufacturing Date: N/A Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION . Parts must be ordered from a dealer or Stocked Hearth and Home Technologies does not sell directly to consumers distributor.
  • Page 38: Accessories

    "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire ACCESSORIES ACCESSORIES Flex Connector Flexcon30 All models Wall Kit Switch w/20' wire MVWS Millivolt On/Off Remote Control Kits RCB, RCM, TLM, WWTD Millivolt Remote Receiver Cover - Embers RRCE Millivolt Remote Receiver Cover - Metal...
  • Page 39: Massachusetts Requirements

    "Duzy" Gas Log Sets – The Look and Feel of a Real Wood Fire Massachusetts Residents Only — Please read and follow these special requirements 2. Approved Carbon Monoxide Detectors. Each carbon NOTE REGARDING VENTED PRODUCTS monoxide detector as required in accordance with the above This product must be installed by a licensed plumber or gas fitter provisions shall comply with NFPA 720 and be ANSI/UL 2034 when installed within the Commonwealth of Massachusetts.
  • Page 40: Warranty

    Limited Lifetime Warranty Policy LIFETIME WARRANTY The following components are warranted for life to the original owner, subject to proof of purchase: Firebox, Combustion Chamber, Heat Exchanger, Grate and Stainless Steel Burners. FIVE YEAR WARRANTY The following components are warranted for 5 years to the original owner, subject of proof of purchase: Ceramic Fiber Logs, Catalytic Filter and Aluminized Burners.