Clearances; Insert Clearances; Mantel Clearances; Hearth Requirements - Vermont Castings VLI31DVNTSC Installation And Operating Instructions Manual

Vlidv series direct vent gas fireplace insert
Table of Contents

Advertisement

VLI31 Fireplace Insert

INSeRt cLeARANceS

No combustibles (ie: drapes, doors) may be within, or
swing within 36" of the front of the insert.
Figure 3 -

Mantel Clearances

MANteL cLeARANceS
NOte: the combustible area above the facing must
not protrude more than 3/4" from the facing. If it does,
it is considered a mantel and must meet the mantel
requirements listed in this manual.
8
Side Wall
10" (254 mm)
Minimum
12" (305 mm)
Minimum
42" (1067 mm)
Minimum
FP1947
insert clearances
9/08
12" (305 mm)
Maximum Depth
12"
(305 mm)
9"
(228 mm)

heARth RequIReMeNtS

The insert must be installed on a noncombustible hearth
extending a minimum of 1" from the fireplace opening
(local codes may require a larger hearth). The hearth must
also extend to both sides of the face (Refer to the table
on Page 7).

cLeARANceS

3/4" (19 mm)
Maximum Depth 
Combustible Facing
NOte: Side clearance to com-
bustibles is 10" (54 mm) from
opening whether it is side wall
or mantel legs.
FP678