Check Gas Type; Install Gas To Insert Location; Installation Items Needed - Vermont Castings VC31LDVINTSC Installation And Operating Instructions Manual

Clean face direct vent fireplace insert
Table of Contents

Advertisement

INstAllAtION

CheCK GAs type

Use proper gas type for the insert you are installing. If you
have conflicting gas type, do not install insert. See dealer
where you purchased the insert for proper insert according
to your gas type.
INstAll GAs pIpING tO INseRt lOCAtION
A qualified installer or service person must
connect appliance to gas supply. Follow all
local codes.

INstAllAtION Items NeeDeD

Make sure you have the items listed below before install-
ing appliance.
Piping (check local codes)
Tee joint
Sealant (resistant to propane/LP gas)
Sediment trap (optional but recommended)
External regulator (supplied by installer)
approved flexible gas line with gas connector (if allowed
by local codes — not provided)
* A CSA design-certified equipment shutoff valve with
1/8" NPT tap is an acceptable alternative to test gauge
connection. Purchase the CSA design-certified equip-
ment shutoff valve from your dealer.
For propane/LP connections only, the installer must supply
an external regulator. The external regulator will reduce
incoming gas pressure. You must reduce incoming gas
pressure to between 11 and 13 inches of water. If you do
not reduce incoming gas pressure, burner system regula-
tor damage could occur. Install external regulator with the
vent pointing down as shown in Figure 18. Pointing the
vent down protects it from freezing rain or sleet.
20304166
Test gauge connection*
Pipe wrench
VC31LDVI/VC31CDVI Gas Fireplace Insert
External
Regual-
tor
Vent
Pointing
Down
Figure 18 -
External Regulator with Vent Pointing Down
(Propane/LP Only)
FP1930
external regulator
use only new black iron or steel pipe. Inter-
9/08
nally tinned copper or copper tubing can be
used per National Fuel Gas Code, section
2.6.3, providing gas meets hydrogen sulfide
limits, and where permitted by local codes.
Gas piping system must be sized to provide
minimum inlet pressure (listed on data plate)
at the maximum flow rate (Btu/hr). undue
pressure loss will occur if the pipe is too
small.
For propane/lp units, never connect insert
directly to the propane/lp supply. this burn-
er system requires an external regulator
(not supplied). Install the external regulator
between the burner system and propane/lp
supply.
100 gal. (min.
Propane/LP
Supply Tank
FP1930
17