INstAllAtION

INseRt plACemeNt

The insert must be placed within a code-conforming
masonry fireplace or a tested and listed zero-clear-
ance (UL-127, solid fuel) fireplace. Repair any fireplace
damage prior to installation.
Because the insert uses a circulation blower, clean the
fireplace, smoke shelf and chimney before installing.
This heater may be placed in a bedroom. Please be
aware of the large amount of heat this appliance pro-
duces when determining a location.
*30 "
(781 mm)
Figure 5 -
Minimum Openings
fp2966
FIREBOX DIMS
20304166
22 "
(568 mm)
20 "
(527 mm)
16 "
(426 mm)
*29N\m" (759 mm) with
control box and bracket
removed.
VC31LDVI/VC31CDVI Gas Fireplace Insert

RemOVe COmmAND CeNteR BRACKet

In order to fit insert into a smaller opening, the command
center bracket may be removed. Refer to Pages 6 and 9
for dimensions.
If the bracket is removed, the small 2" deep, three-sided
surround, model ICF30S3B is required to mount command
center. Refer to surround instructions.
1. Remove command center from bracket by sliding out
to the right. Figure 6
2. Carefully lay unit on its back. Remove two (2) screws
holding bracket to insert. Figure 7
Command Center Bracket
Figure 6
Fp2976
SCS Bracket
Command
Center Bracket
Remove
Screws
Bottom of
Unit
Figure 7
Command
Center
FP2976
FP2980
remove bracket screws
FP2980