Vermont Castings VWDV70 Installation And Operating Instructions Manual

Vermont Castings VWDV70 Installation And Operating Instructions Manual

70" linear wideview direct vent gas fireplace
Table of Contents

Advertisement

70" Linear Wideview
Direct Vent Gas Fireplace
WarnInGs
IF the InForMatIon In these InstructIons
are not FoLLoWeD exactLy, a FIre
or expLosIon May resuLt causInG
property DaMaGe, personaL Injury or
Loss oF LIFe.
Do not store or use gasoline or other
flammable vapors and liquids in the vicinity
of this or any other appliance.
What to Do IF you sMeLL Gas
• Do not try to light any appliance.
• Do not touch any electrical switch; do not
use any phone in your building.
• Immediately call your gas supplier from
a neighbor's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier, call
the fire department.
Installation and service must be performed
by a qualified installer, service agency or
the gas supplier.
WarnInG: Improper installation, adjustment,
alteration, services or maintenance can cause
injury or property damage. refer to this manual.
For assistance or additional information
consult a qualified installer, service agency or
the gas supplier.
this appliance may be installed in an aftermarket*,
permanently located, manufactured home (usa
only) or mobile home, where not prohibited by local
codes.
this appliance is only for use with the type(s) of
gas indicated on the rating plate unless a certified
kit is used.
*aftermarket: completion of sale, not for purpose of resale, from
the manufacturer.
Model: VWDV70
Installation and Operating
Instructions
3735
VWDV70 cover
WarnInG
Due to hIGh teMperatures, the appLIance
shouLD Be LocateD out oF traFFIc anD
aWay FroM FurnIture anD DraperIes.
chILDren anD aDuLts shouLD Be aLerteD
to the haZarDs oF hIGh surFace
teMperature anD shouLD stay aWay to
aVoID Burns or cLothInG IGnItIon.
younG chILDren shouLD Be superVIseD
When they are In the saMe rooM as the
appLIance.
cLothInG or other FLaMMaBLe MaterIaL
shouLD not Be pLaceD on or near the
appLIance.
Keep the rooM area cLear anD Free
FroM coMBustIBLe MaterIaLs, GasoLIne,
anD other FLaMMaBLe Vapors anD
LIquIDs.
InstaLLer: Leave this manual with the appliance.
consuMer: retain this manual for future refer-
ence.
20303735 3/13 Rev. 5

Advertisement

Table of Contents
loading

Summary of Contents for Vermont Castings VWDV70

  • Page 1 70" Linear Wideview Direct Vent Gas Fireplace Model: VWDV70 WarnInGs Installation and Operating IF the InForMatIon In these InstructIons Instructions are not FoLLoWeD exactLy, a FIre or expLosIon May resuLt causInG property DaMaGe, personaL Injury or 3735 Loss oF LIFe.
  • Page 2: Table Of Contents

    VWDV70 Series Gas Fireplace thank you and congratulations on your purchase of a Vermont castings Fireplace. pLease reaD the InstaLLatIon anD operatIon InstructIons BeFore usInG the appLIance! IMportant: read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty.
  • Page 3: Important Safety Information

    IMportant saFety InForMatIon VWDV70 Series Gas Fireplace oWner InstaLLer Please retain these instructions for future reference. Please leave these instructions with the appliance. • read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace.
  • Page 4: Code Approval

    IMportant saFety InForMatIon VWDV70 Series Gas Fireplace 14. Do not use any solid fuels (wood, coal, paper, card- IMportant: board, etc.) in this fireplace. Use only the gas type pLease reaD the FoLLoWInG indicated on rating plate. careFuLLy 15. This appliance, when installed, must be electrically...
  • Page 5: Product Features

    Features VWDV70 Series Gas Fireplace Gas specIFIcatIons & orIFIce sIZe proDuct specIFIcatIons • This appliance has been certified for use with either Max. Min. Input Input orifice sizes natural or propane gas. See appropriate data plates. Model Fuel Btu/hr...
  • Page 6: Fireplace & Framing Dimensions

    FIrepLace & FraMInG DIMensIons VWDV70 Series Gas Fireplace Rough ” (1151 mm) Opening Depth *note: Critical dimension. Do not exceed 10 ” 23 " this dimension for mounting noncombus- (276 mm) (594 mm) tible wall board. Refer to Page 10.
  • Page 7: Fireplace Location

    InForMatIon VWDV70 Series Gas Fireplace FIrepLace LocatIon Plan for the installation of your appliance. This includes determining where the unit is to be installed, the vent con- figuration to be used, framing and finishing details, and whether any optional accessories (i.e. blower, wall switch, or remote control) are desired.
  • Page 8: Clearances

    VWDV70 Series Gas Fireplace cLearances to coMBustIBLes Follow these instructions carefully to ensure safe installation. Failure to follow instructions exactly can create a fire hazard. the appliance cannot be installed on a carpet, tile or other combustible material other than wood flooring.
  • Page 9: Secure Fireplace To Floor Or Framing

    FIrepLace to FLoor or FraMInG VWDV70 Series Gas Fireplace The fireplace must be secured to the floor and/or to framing studs as shown in Figure 7. Use two (2) wood screws or masonry/ concrete screws to secure fireplace to the floor. Use four (4) screws to attach fireplace to framing.
  • Page 10: Noncombustible Facing Installation

    VWDV70 Series Gas Fireplace noncoMBustIBLe FacInG InstaLLa- tIon 4. Tape the seams using a mesh type tape. cautIon: The noncombustible wall board supplied with 5. Mud seams as normal. We recommend using a product this unit can be damaged if dropped or struck. Handle called Durabond high strength compound for the first with care.
  • Page 11: Noncombustible Requirements

    VWDV70 Series Gas Fireplace #8 x 3/4" Self-tapping Screws (supplied) 9” 9” 2” (51 mm) (229 mm) from edge Spacing 1 ” (38 mm) from edge FP2940 note: Use this illustration as a guide when attaching the Figure 9 noncombustible boards to the face of the fireplace.
  • Page 12: Venting Installation

    VentInG InstaLLatIon InForMatIon VWDV70 Series Gas Fireplace read all instructions completely and thoroughly before attempting installation. Failure to do so could result in serious injury, property damage or loss of life. operation of improperly installed and maintained venting system could result in serious injury, property damage or loss of life.
  • Page 13: Installation Planning

    VentInG InstaLLatIon VWDV70 Series Gas Fireplace InstaLLatIon pLannInG never run the vent pipe level down. this There are two basic types of direct-vent installation: may cause excessive temperatures which • Horizontal Termination could cause a fire. • Vertical Termination It is important to select the proper length of vent pipe for For two-story applications, firestops are required at each the type of termination you choose.
  • Page 14: General Venting - Termination Location

    3. Vermont Castings Group assumes no responsibility for the  only permitted if veranda, porch, deck or balcony is fully open on a improper performance of the appliance when the venting minimum 2 sides beneath the floor: system does not meet these requirements.
  • Page 15: Termination Clearances

    VentInG InstaLLatIon VWDV70 Series Gas Fireplace Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Alcove Applications* Outside Corner Combustible 6" (152 mm) Combustible 6" (152 mm) Noncombustible 2" (51 mm) Noncombustible 2" (51 mm) Balcony -...
  • Page 16: Vertical Sidewall Installation

    VentInG InstaLLatIon VWDV70 Series Gas Fireplace VertIcaL sIDeWaLL InstaLLatIon step 1 Locate vent opening on the wall. It may be necessary to first position the fireplace and measure to obtain hole lo- cation. Depending on whether the wall is combustible or noncombustible, cut opening to size.
  • Page 17: Vertical/Horizontal Termination Configurations

    VentInG InstaLLatIon VWDV70 Series Gas Fireplace 36" VertIcaL/horIZontaL terMInatIon 36" (914 mm) conFIGuratIons (914 mm) Max. Max. since it is very important that the venting system main- tain its balance between the combustion air intake and 36” the flue gas exhaust, certain limitations as to vent con- (914 mm) figurations apply and must be strictly adhered to.
  • Page 18: Below Grade Installation

    VentInG InstaLLatIon VWDV70 Series Gas Fireplace Example: Elbow 1 = 90° 7. Level the soil so as to maintain a 4" clearance below Elbow 2 = 45° snorkel. Figure 19 Elbow 3 = 45° Screws Elbow 4 = 90° Total Angular Variation = 270°...
  • Page 19: Vertical Through-The-Roof

    VentInG InstaLLatIon VWDV70 Series Gas Fireplace Elbow 1 = 90° Example: VertIcaL (throuGh-the-rooF) Elbow 2 = 45° appLIcatIons Elbow 3 = 45° This gas fireplace has been approved for, Elbow 4 = 90° • Vertical installations up to 40' (12 m) in height. Up to Total Angular Variation = 270°...
  • Page 20: Installation For Vertical Termination

    VentInG InstaLLatIon VWDV70 Series Gas Fireplace InstaLLatIon For VertIcaL terMInatIon 1. Determine the route your vertical venting will take. If Roof Flashing ceiling joist, roof rafters or other framing will obstruct the venting system, consider an offset. Refer to Figure 26 to avoid cutting load bearing members.
  • Page 21 VentInG InstaLLatIon VWDV70 Series Gas Fireplace terMInatIon heIGhts For Vents aBoVe FLat or 3. Cut a hole in the roof using the locating hole as a center sLopeD rooFs point. (Cover any exposed open vent pipes before cutting hole in roof). The 10Z\x"x10Z\x" (241 x 241 mm) Horizontal Overhang hole must be measured on the horizontal.
  • Page 22: Flex Vent Installation

    FLex Vent InstaLLatIon VWDV70 Series Gas Fireplace 1. Flexible UL1777 listed venting may be used in any UL1777 venting application where rigid direct vent components Flex Vent can be used. all restrictions, clearances and allow- ances that pertain to the rigid piping apply to the flexible venting.
  • Page 23 D. Attaching flexible venting to vertical termination opposite one another and below the gear assemblies. clamp. 1. When using Duravent pipe, an Vermont Castings 5. Use only listed an approved terminations and Group flex-to-pipe adapter (FPA) and/or rigid pipe accessories, installed per the termination instruc- section(s) is required to connect the flexible vent tions and Figure 34.
  • Page 24: Fireplace Installation

    FIrepLace InstaLLatIon VWDV70 Series Gas Fireplace checK Gas type Use proper gas type for the fireplace you are installing. 100 gallon (min) If you have conflicting gas type, do not install fireplace. Propane/LP Supply External See dealer where you purchased the fireplace for proper...
  • Page 25: Install Gas Piping To Fireplace/Burner System

    FIrepLace InstaLLatIon VWDV70 Series Gas Fireplace a manual shutoff valve must be installed only persons licensed to work with gas piping upstream of the appliance. union tee may make the necessary gas connections and plugged 1/8" npt pressure tapping to this appliance.
  • Page 26: Check Gas Pressure

    - checK Gas pressure VWDV70 Series Gas Fireplace 1. Check gas type. The gas supply must be the same as stated on the appliance’s rating decal. If the gas supply Pressure Inlet is different from the fireplace, stop! Do not install the appliance.
  • Page 27: Electrical Installation

    InstaLLatIon VWDV70 Series Gas Fireplace junctIon Box WIrInG 1. This should be done before framing the fireplace. Wire the receptacle into an electrical circuit. Wire with mini- mum 60° C wire in accordance with prevailing codes. 2. Remove the external junction box cover by removing the screw from the side of the outside firebox wall.
  • Page 28: Scs Wiring Diagram

    InstaLLatIon VWDV70 Series Gas Fireplace Light 300 Watt Max. Pilot A/C MODULE WHITE BLACK WHITE Opt. Blower BLACK BLACK Opt. Aux. WHITE GREEN 300 Watt RF Receiver Max. On/off Button Control Board BLACK/Thermopile RED/Thermopile Conversion NG/LP Sensing Igniter / Sparker...
  • Page 29: Glass Frame Removal

    GLass reMoVaL & LIGht pLaceMent VWDV70 Series Gas Fireplace GLass FraMe reMoVaL 1. Use glass frame latch tool packed with unit to unlatch the three (3) frame latches. 2. Pull frame away from unit and lift up and away. cau- tIon: Frame is heavy: lifting may require two (2) people.
  • Page 30: Glass & Stone Placement

    GLass & stone pLaceMent VWDV70 Series Gas Fireplace GLass anD stone pLaceMent cautIon: Do not allow these stones to contact any part of the pilot parts. Do not allow any of the pilot flames to If you will be installing the optional accessory log set, contact any stones.
  • Page 31: Accessory Log Installation

    LoG InstaLLatIon VWDV70 Series Gas Fireplace Figure 47 - LG1115 Stone & Glass Placement accessory LoG InstaLLatIon: MoDeL LKW70 LG1115 WarnInG: turn fireplace off and allow to cool com- VWDV70 stones pletely before beginning installation. WarnInG: only a qualified service person should service or repair this fireplace.
  • Page 32 LoG InstaLLatIon VWDV70 Series Gas Fireplace 4. Place the large rear right log #2 by align- ing the three (3) holes in the bottom of Large Rear Right the log with the three (3) pins. Figure Log #2 5. Place decorative colored glass supplied with fireplace.
  • Page 33 LoG InstaLLatIon VWDV70 Series Gas Fireplace 8. Place the medium top right log Medium Top Right #5 onto the center of the rear Log #5 right log #2 by aligning the re- cess with the key protrusion on the rear right log. Figure 53...
  • Page 34 LoG InstaLLatIon VWDV70 Series Gas Fireplace 10. Place the small front right log #7 on top of the decorative glass towards the right side of the hearth. Figure 55 IMportant: Do not place this log in or near the burner port area.
  • Page 35: Operating Instructions

    - operatInG InstructIons VWDV70 Series Gas Fireplace For your saFety reaD BeFore LIGhtInG If you do not follow these instruction exactly, a fire or explosion may result causing property damage, personal injury or loss of life. a. This appliance is equipped with an ignition device which automatically lights the pilot. Refer to the instructions.
  • Page 36: Operating Instructions

    - operatInG InstructIons VWDV70 Series Gas Fireplace operatInG InstructIons 1. stop! Read the safety information above. 2. This appliance is equipped with an ignition device which automatically lights the burner. Do not try to light the burner by hand.
  • Page 37: Signature Command System Operation

    InstructIons VWDV70 Series Gas Fireplace Features To Thermopile RF Receiver command center ON/OFF To Sensor • Easy Access Function Operation and System Configura- To Sparker tion • Operation Confirmation/Fault Diagnostic Indications NG/LP (LED/Buzzer) Conversion • ON/OFF/HI/Med/Low Operation •...
  • Page 38 InstructIons VWDV70 Series Gas Fireplace systeM conFIGuratIon/setup note: By disabling this feature, your fireplace may con- All System configuration/setup is done on the Command tinue to operate unattended. Center. 2. When the master switch is in the ON position (“-”), press-...
  • Page 39 InstructIons VWDV70 Series Gas Fireplace FunctIons/operatIon 2. Press the OFF button to decrease flame height. The first two presses will decrease the flame height to medium turning on the fireplace and low. 1. Turn on the master switch and wait for a beep.
  • Page 40: Touch Screen Remote Control Operation

    VWDV70 Series Gas Fireplace Due to the sensitive temperature monitoring components in the transmitter, it is necessary to allow the transmitter to stabilize to room tem- perature before accurate room temperatures are displayed. If the transmitter is activated...
  • Page 41 VWDV70 Series Gas Fireplace setting privacy code on transmitter: Master Switch Figure 60 The remote transmitter privacy code is preset in factory. In the event of activation or interference from other nearby transmissions, change the code using the following pro-...
  • Page 42 VWDV70 Series Gas Fireplace c. Slide down on the arrow buttons to exit TIMER 1. Press the ON/up button to turn on the fireplace. The mode and shut off the fireplace. flame icon on the LCD displays High.
  • Page 43 ON/UP button at the same time for 3 seconds and the new settings will be transmitted to the receiv- again. Blower speed control (not used with VWDV70) 6. The default settings are 5 minutes for the On Delay Figure 67 Time and 8 minutes for the Off Delay Time, as shown.
  • Page 44: Safety Features

    VWDV70 Series Gas Fireplace 5. When the light button is flashing, slide up and down on n safety Features the arrow buttons will turn the light brightness to HIGH 1. Low Battery Detection or Off directly without pressing the light button again to...
  • Page 45: Troubleshooting

    VWDV70 Series Gas Fireplace n using the Mounting Base The transmitter comes with a mounting base which allows you to hang the transmitter on the wall. 1. Secure the mounting base on the wall with supplied screws.
  • Page 46: Fuel Conversion

    FueL conVersIon VWDV70 Series Gas Fireplace this Kit Must be Installed by a qualified service agency conVersIon InstructIons this conversion kit shall be installed by a quali- fied service agency in accordance with the 1. Using the hand tool provided with the unit, remove manufacturer’s instructions and all applicable...
  • Page 47 FueL conVersIon VWDV70 Series Gas Fireplace 13. For conversion to Lp: Unscrew three (3) air shutters A/C Module Control Board through lens opening and discard. Figure 75. note: Replace screws. For conversion to natural gas: Install new air shut- ters provided and adjust to 1/8" opening. Figure 76...
  • Page 48 FueL conVersIon VWDV70 Series Gas Fireplace 2. Pull up on hood testing engine / Burner assembly to remove 1. Turn on the gas shut off valve. 1. Partially 2. Follow Lighting Instructions on the unit. Light the unit disengage C-clamp according to Homeowner’s Manual.
  • Page 49: Cleaning And Maintenance

    MaIntenance VWDV70 Series Gas Fireplace turn off gas before servicing fireplace. It is recommended that a qualified service technician perform these check-ups at the beginning of each heating season Sensor Burner, pILot anD controL coMpart- Ment Thermopile Keep the control compartment, stones, and burner areas surrounding the stones clean by vacuuming or brushing at least twice a year.
  • Page 50: Vent System

    MaIntenance VWDV70 Series Gas Fireplace Vent systeM The fireplace and venting system should be inspected To clean glass door, follow “Glass Removal” procedure before initial use and at least annually by a qualified field outlined in the Final Installation section. Film deposit on the service person.
  • Page 51: Troubleshooting

    VWDV70 Series Gas Fireplace sIGnature coMManD systeM OPERATION FAULT ACTION DIAGNOSIS Using Battery polarity wrong? Re-install batteries battery? Make sure Command Install batteries and/or Battery voltage low? Change batteries Center and plug in the AC board No beep in about...
  • Page 52: Replacement Parts

    VWDV70 Series Gas Fireplace FIreBox coMponents anD accessorIes ref. Description qty. VWDV70 Bulb (35 Watt) 78D0007 Bulb Socket 73D4521K Glass Frame Assembly 20303344 Junction Box Assembly (not shown) 26D2128 Wire (Lighting) 20303729 Lightwire Junction Box w/Cover 20303352 3735...
  • Page 53: Signature Command System

    VWDV70 Series Gas Fireplace sIGnature coMManD systeM & enGIne 3735 VWDV70 engine parts 20303735...
  • Page 54 VWDV70 Series Gas Fireplace sIGnature coMManD systeM & enGIne Item Description qty. VWDV70ntsc Base Engine 20302845K Gasket, Engine Base 20302866 Gasket, Access Panel 20302867 Assy, Burner 20303226 Support, Burner 20303233 Bracket, Tube Support 20303730 Pilot Assy 80D0006 Venturi, Gasket...
  • Page 55 VWDV70 Series Gas Fireplace GLass Ref. Description qty. part no. Glass Set, Onyx Glass Set, Diamond stones Stone M Black 20303041K Stone M Sand 20303042K Stone M White 20303043K Stone M Dark Gray 20303044K Stone White 78D0136K Stone Sand...
  • Page 56: Venting Components

    VentInG coMponents VWDV70 Series Gas Fireplace Vent coMponents For 5" x 8" 730024 KHLDV vent parts 20303735...
  • Page 57 VentInG coMponents VWDV70 Series Gas Fireplace current Duravent Duravent or Vermont or Vermont qty./ castings Group castings Group selkirk Metal-Fab Item Description part no. part no. part no. part no. Horizontal Termination Cap w/Built-In Vinyl Siding BHR58TK9 Standoff Heat Deflector, Firestop and Adjustable Pipe 11"...
  • Page 58: Massachusetts Residents Only

    VWDV70 Series Gas Fireplace Massachusetts A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height This product must be installed by a licensed plumber or...
  • Page 59: Warranty

    After installation, if any of the components manufactured by Vermont Castings Group in the appliance are found to be defec- tive in materials or workmanship, Vermont Castings Group will, at its option, replace or repair the defective components at no charge to the original owner.
  • Page 60: Efficiencies

    71.4 VWDV70PTSC 79.8* 77.5* Recherchez dans la brochure *After conversion to LP. les caractéristique de rendement énergétique de foyer au gaz Énerguide Based on CSA P.4.1-09 Selon CSA P.4.1-09 Vermont castings Group 149 Cleveland Drive • Paris, Kentucky 40361 www.vermontcastingsgroup.com...

Table of Contents