CONTENTS
Displays
Remaining Battery Level and Audio Level Displays
Remaining tape length
When the amount remaining
on the tape is more than
30 minutes long, all seven seg-
ments up to the "F" position ap-
pear lit.
When it is less than 30 minutes
long, one segment will go off
for every 5-minute reduction in
the length.
Remaining battery level
When the digital display (%
display) battery is used, the
7 segments light up all the way
to the "F" position if the remain-
ing battery level is more than
70%.
If the remaining battery level is
under 70%, one of the seg-
ments goes off for each further
10% reduction in the remaining
level.
VTR Section Operation/Status-Related Displays
Lights
SLAVE
TCG
HOLD
WIDE
Error code:
Indicated in the display
window.
Warning display
RF:
SERVO: Lights when the servo is out of order.
HUMID: Lights when condensation occurs on the head drum.
SLACK: Lights when tape wind-up trouble occurs.
ÁSee "Warning System" (page 150) for a detailed description.
SLAVE TCG HOLD WIDE
h
min
s
E
TAPE
E
BATT
RF SERVO HUMID SLACK
SLAVE TCG HOLD
h
min
s
E
TAPE
E
BATT
RF SERVO HUMID SLACK
Lights when video head clogging occurs.
– 65 (E) –
EMPHASIS
0
10
frm
F
20
F
30
40
CH1
dB
WIDE
EMPHASIS
0
10
frm
F
20
F
30
40
CH1
dB
Audio CH level meter
CH2
CH2