Technical Data Mod. M296.24Sm/C - Biasi Riva Plus HE M296.24SM User Manual And Installation Instructions

Wall hung, fanflue, roomsealed, high efficiency gas boiler
Table of Contents

Advertisement

4.3
Technical data mod.
M296.24SM/C
Heat input
Nominal net
(ch - dhw)
(A)
Nominal gross
(ch - dhw)
(B)
Minimun net
ch - dhw
(A)
Minimun gross
ch - dhw
(B)
Useful output
Maximun (ch - dhw)
Minimun (ch - dhw)
Maximun condensing (ch - dhw)
Minimun condensing (ch - dhw)
Central heating
Min/Max flow temperature settings*
Minimum return temperature
Maximum pressure
Minimum pressure
Available head (in 1000 l/h)
Seasonal effiency G20
Seasonal effiency G30 G31
* to the minimum useful output
- 24 -
TECHNICAl INFoRMATIoN
kW
25,0
BTU/h 85304
kW
27,8
BTU/h 94687
kW
7,5
BTU/h 25591
kW
8,3
BTU/h 28406
kW
24,4
BTU/h 83256
kW
7,3
BTU/h 24909
kW
26,3
BTU/h 89739
kW
7,8
BTU/h 26615
°C
50-85
°C
40
kPa
250
bar
2,5
kPa
30
bar
0,3
kPa
25
bar
0,25
%
88,0
%
89,0
(C)
Domestic hot water
Min/Max temperature settings
Maximum pressure
Minimum pressure
Flow rate minimun
Flow rate 30° rise
(D)
Flow rate 35° rise
(D)
Flow rate 40° rise
(D)
Gas supply pressures
Gas
Nom
Natural G20
Min
Max
Nom
Butane G30
Min
Max
Nom
Propane G31
Min
Max
1 mbar approximately equals 10 mm H
°C
35 - 55
kPa
1000
bar
10
kPa
30
bar
0,3
l/min
2,5
l/min
11,6
l/min
10,0
l/min
8,7
Pa
mbar
2000
20
1700
17
2500
25
2900
29
2000
20
3500
35
3700
37
2500
25
4500
45
O
2

Hide quick links: