Sony UWP-V1 Service Manual page 83

Uhf wireless microphone package
Hide thumbs Also See for UWP-V1:
Table of Contents

Advertisement

Connections
. For connecting the DC power supply, refer to step
"3. Connecting the DC power supply" in Section 2-6-2.
. For the connection to the MIC IN connector (CN1), refer
to the section "4. Reference Frequency Deviation
Adjustment".
RF IN
SMA-BNC
conversion
Modulation
connector
analyzer
MM-SMA
conversion
connector
CN1
CN101
MB-1094 board
MB-1094 board
(A side)
(B side)
Procedure
1. Connect the audio analyzer (distortion analyzer) to the
AF OUT connector for the modulation analyzer.
2. Set the audio analyzer to distortion measurement
(DISTORTION mode).
3. Input 1 kHz, _60 dBV (_57.8 dBm) signal to the AF
INPUT connector from audio analyzer (oscillator).
(0 dBV = 1 Vrms)
4. Check that the distortion analyzer reading is less than
0.90%.
5. Input 1 kHz, _34 dBV (_31.8 dBm) signal to the AF
INPUT connector.
6. Check that the distortion analyzer reading is less than
3.2%.
UWP Series
Oscilloscope
AF
OUT
Distortion
analyzer
Oscillator
Audio analyzer
Level meter
7. S/N Check
Equipment and Tools
. DC power supply
DC output voltage : +3.0 ± 0.1Vdc
. DC ammeter
. Audio analyzer
. Modulation analyzer
MEASUREMENT
MEASUREMENT RANGE : ± 40 kHz
HPF
: 50 Hz
LPF
: 15 kHz or 20 kHz
DE EMPHASIS
: 50 usec
. Oscilloscope
. MM-SMA conversion connector
(SONY Part No. J-6402-490-A)
. SMA-BNC conversion connector
(SONY Part No. J-6402-480-A)
Switch and Control Setting
MB-1094 board
Transmission channel
U30 model
; 32-01 channel (578.125 MHz)
U42 model
; 44-01 channel (650.125 MHz)
U6264 model ; 64-01 channel (770.125 MHz)
U6668 model ; 68-01 channel (794.125 MHz)
CE62 model
; Group 00, 63-32 channel (810.000 MHz)
CE67 model
; Group 00, 68-32 channel (850.000 MHz)
Attenuation setting
Accumulated time setting
MIC/LINE Select Switch (S1) : MIC
n
Take note of the settings before starting the confirmation
work.
After confirmation is completed, return the settings to
the original setting before change.
Connections
. Same as "6. Distortion Ratio Check".
. For connecting the DC power supply, refer to step
"3. Connecting the DC power supply" in Section 2-6-2.
Procedure
1. Connect the audio analyzer (level meter) to the AF OUT
connector for the modulation analyzer.
2. Set the modulation analyzer.
3. Input 1 kHz, _60 dBV (_57.8 dBm) signal to the AF
INPUT connector from audio analyzer (oscillator).
(0 dBV = 1 Vrms)
4. Set the audio analyzer to S/N measurement (with A-
weighting filter).
5. Check that the S/N reading is more than 28 dB.
n
Perform the checking with the AF INPUT connector
short-circuit.
: FM
: 0 dB
: "00 : 00"