2. Powered Mixer SRP-X500P / SRP-X700P
When using the SRP-X500P
Removal
1. Pull the latch securing the tuner unit to the side and
pull out the tuner unit URX-M2.
Installation
1. Check the top and bottom sides of the tuner unit, and
then insert it into the slot.
n
When installing the tuner unit, insert it fully into the
tuner slot of the SRP-X500P and secure it with the
latch on the slot.
UWP Series
URX-M2
Latch
URX-M2
Latch
When using the SRP-X700P
Removal
1. Insert a screwdriver into the hole under the lower part
of the tuner slot and remove the URX-M2.
Screwdriver : Shaft diamter is between 2 to 4 mm
Shaft length is 30 mm or longer
Installation
The SRP-X700P Powered Mixer can accommodate up to 2
URX-M2.
1. Remove the tuner slot cover from the SRP-X700P and
inspect the top and bottom sides of the URX-M2.
2. Holding the tuner module on both sides, insert it into
the slot.
URX-M2
URX-M2