Sony UWP-V1 Service Manual page 72

Uhf wireless microphone package
Hide thumbs Also See for UWP-V1:
Table of Contents

Advertisement

(5) RF Squelch Level/RF Indicator Check
1. Set the URX-P2 as follows :
Channel setting :
U30 model ; Group 03, 3201 channel
U42 model ; Group 03, 4401 channel
CE62 model ; Group 04, 6332 channel
CE67 model ; Group 04, 6832 channel
KR model
; Group 12, 6001 channel (746.125 MHz)
RF squelch : ON (Normal mode)
Monitor level :MON.01 (minimum value)
2. Connect the signal generator to the CN201/RF-130
board with the MM-SMA conversion connector and the
RF adjusting cable.
3. Set the signal generator as follows :
Signal generator setting
FREQUENCY (carrier frequency) :
U30 model
; 578.125 MHz
U42 model
; 650.125 MHz
CE62 model
; 810.000 MHz
CE67 model
; 850.000 MHz
KR model
; 746.125 MHz
RF OUTPUT (Output level) : 60 dBuV
MODULATION (Modulation frequency) : 1 kHz
DEVIATION (Frequency deviation)
4. Check that RF Indicator LED lights (green) and "NO
TONE" message appears on LCD (URX-P2).
5. Change the RF OUTPUT (output level) of the signal
generator as shown below.
RF OUTPUT (output level) : 5 dBuV
6. Check that RF Indicator LED goes off (green) and "NO
TONE" message disappears on LCD (URX-P2).
7. Increase gradually the RF OUTPUT (output level) of
the signal generator. Check that RF OUTPUT (output
± 5 dB at when RF Indicator lights
level) is 15 dBuV
EMF
(green LED) and "NO TONE" message appears on
LCD (URX-P2).
RF
RF indicator lights.
8. Connect the signal generator to the CN101/RF-130
board with the MM-SMA conversion connector and the
RF adjusting cable.
9. Perform the procedures 3 to 7 above.
2-52
(= _53 dBm)
EMF
: OFF
(= _108 dBm)
EMF
AF
10. Set the channel and FREQUENCY (carrier frequency)
of the signal generator as shown 1 and 2 below.
Perform the procedures 1 to 9 above, for each channel
setting (1 and 2).
1 Channel setting :
U30 model
; Group 01, 3001 channel (566.125 MHz)
U42 model
; Group 01, 4201 channel (638.125 MHz)
CE62 model ; Group 01, 6201 channel (798.125 MHz)
CE67 model ; Group 01, 6701 channel (838.125 MHz)
KR model
; Group 00, 5901 channel (740.125 MHz)
Signal generator setting :
FREQUENCY (carrier frequency)
U30 model
; 566.125 MHz
U42 model
; 638.125 MHz
CE62 model
; 798.125 MHz
CE67 model
; 838.125 MHz
KR model
; 740.125 MHz
2 Channel setting :
U30 model ; Group 00, 3347 channel (589.875 MHz)
U42 model ; Group 00, 4547 channel (661.875 MHz)
CE62 model ; Group 00, 6463 channel (821.875 MHz)
CE67 model ; Group 00, 6964 channel (862.000 MHz)
KR model
; Group 00, 6047 channel (751.875 MHz)
Signal generator setting:
FREQUENCY (carrier frequency):
U30 model
; 589.875 MHz
U42 model
; 661.875 MHz
CE62 model
; 821.875 MHz
CE67 model
; 862.000 MHz
KR model
; 751.875 MHz
UWP Series