Sony UWP-V1 Service Manual page 28

Uhf wireless microphone package
Hide thumbs Also See for UWP-V1:
Table of Contents

Advertisement

Connections
. For connecting the DC power supply, refer to step
"3. Connecting the DC power supply" in Section 2-1-2.
. For the connection to the AF IN connector (CN1), refer
to the section "4. Reference Frequency Deviation
Adjustment".
MM-SMA conversion connector and
SMA-BNC conversion connector
AF input
MIC / LINE
connector
change switch
(S401 / RF-131 board)
RF-131 board
Procedure
1. Connect the audio analyzer (distortion analyzer) to the
AF OUT connector for the modulation analyzer.
2. Set the audio analyzer to distortion measurement
(DISTORTION mode).
3. Input 1 kHz, _60 dBV (_57.8 dBm) signal to the AF
INPUT connector from audio analyzer (oscillator).
(0 dBV = 1 Vrms)
4. Check that the distortion analyzer reading is less than
1.0%.
5. Input 1 kHz, _23 dBV (_20.8 dBm) signal to the AF
INPUT connector.
6. Check that the distortion analyzer reading is less than
1.0%.
2-8
Level meter
Audio analyzer
Oscillator
Distortion
analyzer
RF
AF
IN
OUT
Modulation
analyzer
Oscilloscope
CN301
7. S/N Check
Equipment and Tools
. DC power supply
DC output voltage : +3.0 ± 0.1Vdc
. DC ammeter
. Audio analyzer
. Modulation analyzer
MEASUREMENT
MEASUREMENT RANGE : ± 40 kHz
HPF
LPF
DE EMPHASIS
. Oscilloscope
. MM-SMA conversion connector
(SONY Part No. J-6402-490-A)
. SMA-BNC conversion connector
(SONY Part No. J-6402-480-A)
Switch and Control Setting
Transmission channel
U30 model
; 32-01 channel (578.125 MHz)
U42 model
; 42-01 channel (650.125 MHz)
CE62 model ; Group 00, 63-32 channel (810.000 MHz)
CE67 model ; Group 00, 68-32 channel (850.000 MHz)
KR model
; 60-01 channel (746.125 MHz)
MIC/LINE change switch
(S401/RF-131 board) :
Attenuation setting :
Accumulated time setting : "00 : 00"
n
Take note of the settings before starting the confirmation
work.
After confirmation is completed, return the settings to
the original setting before change.
Connections
. Same as "6. Distortion Ratio Check".
. For connecting the DC power supply, refer to step
"3. Connecting the DC power supply" in Section 2-1-2.
Procedure
1. Connect the audio analyzer (level meter) to the AF OUT
connector for the modulation analyzer.
2. Set the modulation analyzer.
3. Input 1 kHz, _60 dBV (_57.8 dBm) signal to the AF
INPUT connector from audio analyzer (oscillator).
(0 dBV = 1 Vrms)
4. Set the audio analyzer to S/N measurement (with A-
weighting filter).
5. Check that the S/N reading is more than 30 dB.
n
Perform the checking with the AF INPUT connector
short-circuit.
: FM
: 50 Hz
: 15 kHz or 20 kHz
: 50 usec
MIC
0 dB