5. Maximum Frequency Deviation
Adjustment
Equipment and Tools
. DC power supply
DC output voltage : +3.0 ± 0.1Vdc
. DC ammeter
. Audio analyzer
. Modulation analyzer
MEASUREMENT
MEASUREMENT RANGE : AUTO or ± 100 kHz
HPF
LPF
DE EMPHASIS
. Oscilloscope
. Adjustor (SONY part No. 7-721-052-81)
. MM-SMA conversion connector
(SONY Part No. J-6402-490-A)
. SMA-BNC conversion connector
(SONY Part No. J-6402-480-A)
Switch and Control Setting
MB-1094 board
Transmission channel
U30 model
; 32-01 channel (578.125 MHz)
U42 model
; 44-01 channel (650.125 MHz)
U6264 model ; 64-01 channel (770.125 MHz)
U6668 model ; 68-01 channel (794.125 MHz)
CE62 model
; Group 00, 63-32 channel (810.000 MHz)
CE67 model
; Group 00, 68-32 channel (850.000 MHz)
Attenuation setting
Accumulated time setting
MIC/LINE Select Switch (S1) : MIC
n
Note down the setting position before the adjustment.
After the Adjustment complete, set the original position.
Connections
. Same as "4. Reference Frequency Division adjustments".
. For connecting the DC power supply, refer to step
"3. Connecting the DC power supply" in Section 2-6-2.
Procedure
1. Input 1 kHz, _30 dBV (_27.8 dBm) signal to the AF IN-
PUT connector (with Mic input cable). (0 dBV = 1 Vrms)
2. Connect a modulation analyzer to the antenna terminal
(CN101) via the MM-SMA conversion connector and
the SMA-BNC conversion connector.
2-62
: FM
: 50 Hz
: 15 kHz or 20 kHz
: 50 usec
: 0 dB
: "00 : 00"
3. Adjust 1RV1 so that the frequency deviation for the
modulation analyzer reading meets the following speci-
fication.
Specification : Frequency deviation = ± 35 kHz ± 0.5 kHz
Adjustment : 1RV1/MB-1094 board (A side)
4. Input 1 kHz, _5 dBV (_2.8 dBm) signal to the MIC
INPUT connector (with Mic input cable).
5. Adjust 1RV2 so that the frequency deviation for the
modulation analyzer reading meets the following speci-
fication.
Specification : Frequency deviation = ± 40 kHz ± 0.5 kHz
Adjustment : 1RV2/MB-1094 board (A side)
6. Distortion Ratio Check
Equipment and Tools
. DC power supply
DC output voltage : +3.0 ± 0.1Vdc
. DC current meter
. Audio analyzer
. Modulation analyzer
MEASUREMENT
MEASUREMENT RANGE : AUTO or ± 40 kHz
HPF
LPF
DE EMPHASIS
. Oscilloscope
. MM-SMA conversion connector
(SONY Part No. J-6402-490-A)
. SMA-BNC conversion connector
(SONY Part No. J-6402-480-A)
Switch and Control Setting
MB-1094 board
Transmission channel
U30 model
; 32-01 channel (578.125 MHz)
U42 model
; 44-01 channel (650.125 MHz)
U6264 model ; 64-01 channel (770.125 MHz)
U6668 model ; 68-01 channel (794.125 MHz)
CE62 model
; Group 00, 63-32 channel (810.000 MHz)
CE67 model
; Group 00, 68-32 channel (850.000 MHz)
Attenuation setting
Accumulated time setting
MIC/LINE Select Switch (S1) : MIC
n
Take note of the settings before starting the confirmation
work.
After confirmation is completed, return the settings to
the original setting before change.
: FM
: 50 Hz
: 15 kHz or 20 kHz
: 50 usec
: 0 dB
: "00 : 00"
UWP Series