Sony UWP-V1 Service Manual page 58

Uhf wireless microphone package
Hide thumbs Also See for UWP-V1:
Table of Contents

Advertisement

(6) RF Level Indicator Check
Procedure
n
The checking procedures describe that the URX-M2 (to be
adjusted) is installed into the Tuner [1] slot on the MB-X6 or
MB-806.
1. Set the URX-M2 and MB-X6/MB-806 as follows :
. URX-M2 Front panel (Tuner [1])
Channel setting :
U30 model
; Group 03, 32-01 channel (578.125 MHz)
U42 model
; Group 03, 44-01 channel (650.125 MHz)
CE62 model ; Group 04, 63-32 channel (810.000 MHz)
CE67 model ; Group 04, 68-32 channel (850.000 MHz)
KR model
; Group 12, 60-01 channel (746.125 MHz)
Muting : ON (Normal mode)
. MB-X6/MB-806 Rear panel
ATT (ANTENNA A, B) switch : 0 dB
2. Connect the signal generator to the ANTENNA A IN
connector with DC cut fixture.
3. Set the signal generator as follows :
Signal generator setting
FREQUENCY (carrier frequency) :
U30 model
; 578.125 MHz
U42 model
; 650.125 MHz
CE62 model ; 810.000 MHz
CE67 model ; 850.000 MHz
KR model
; 746.125 MHz
RF OUTPUT (Output level) : 0 dBuVEMF (= _113 dBm)
MODULATION (Modulation frequency) : 1 kHz
DEVIATION (Frequency deviation)
4. Increase gradually the output level from the signal gen-
erator, and check that the output level of the signal gen-
erator is as follows when the RF input level indicator
(Tuner [1]) lights.
RF level indicator (green)
lights in of Tuner [1]
[1]
[1]
[1]
[1]
LCD :
Lighting
LCD :
Lighting
LCD :
Lighting
LCD :
Lighting
2-38
: ± 5 kHz
Signal generator output level
± 5 dB
25 dBuV
EMF
± 5 dB
35 dBuV
EMF
± 5 dB
45 dBuV
EMF
± 5 dB
55 dBuV
EMF
5. Connect the signal generator to the ANTENNA B IN
connector with DC cut fixture.
6. Perform the procedures 3 to 4 above.
7. Set the channel setting (Tuner [1]) and FREQUENCY
(carrier frequency) of the signal generator as shown 1
and 2 below.
Perform the procedures 1 to 6 above, for each channel
setting (1 and 2).
1 Channel setting :
U30 model ; Group 01, 30-01 channel (566.125 MHz)
U42 model ; Group 01, 42-01 channel (638.125 MHz)
CE62 model ; Group 01, 62-01 channel (798.125 MHz)
CE67 model ; Group 01, 67-01 channel (838.125 MHz)
KR model
; Group 00, 59-01 channel (740.125 MHz)
Signal generator setting :
FREQUENCY (carrier frequency)
U30 model
; 566.125 MHz
U42 model
; 638.125 MHz
CE62 model ; 798.125 MHz
CE67 model ; 838.125 MHz
KR model
; 740.125 MHz
2 Channel setting :
U30 model ; Group 00, 33-47 channel (589.875 MHz)
U42 model ; Group 00, 45-47 channel (661.875 MHz)
CE62 model ; Group 00, 64-63 channel (821.875 MHz)
CE67 model ; Group 00, 69-64 channel (862.000 MHz)
KR model
; Group 00, 60-47 channel (751.875 MHz)
Signal generator setting:
FREQUENCY (carrier frequency):
U30 model
; 589.875 MHz
U42 model
; 661.875 MHz
CE62 model ; 821.875 MHz
CE67 model ; 862.000 MHz
KR model
; 751.875 MHz
UWP Series

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Uwp-x8Uwp-v2Uwp-x7Uwp-v6

Table of Contents