Fitting the Hob

Unpacking the hob:
Take care not to lose or mishandle any
15mm
parts.
Ventilation slot > 30mm
Fig.5
Fitting position of the hob:
This appliance must be installed a minimum of 50mm from any
back wall and a minimum of 150mm away from any adjacent vertical
surfaces, e.g. a tall cupboard end panel. This may be reduced to
100mm if the adjacent surface is resistant to fire (tiles or steel, for
example). These dimensions are shown in Fig.5.
If fitting a cooker hood above the hob:
If a cooker hood is to be installed above the hob, the height of
the hood above the hob must be at least 700mm (750mm is
recommended) (Fig.6).
If the instructions supplied with the hood dictate that the hood must
be installed at a height greater than 700mm, then that height is the
minimum required.
Wall furniture requirements:
The minimum height of any cabinet immediately above the hob is
900mm.
The minimum height of any adjacent units (including light pelmets) is
400mm, unless they are manufactured from a material resistant to fire
(steel, for example).