Item
11. SLEEP MODE
When pushing [SLEEP MODE] button on the remote
operation
controller, a quiet and mild operation is performed by
reducing the fan speed and the compressor speed.
<Cooling operation>
This function operates the air conditioner with the differ-
ence between the set and the room temperature as shown
in the following figure.
The time correction is performed for 8 minutes each.
TA-Tsc
[˚C]
+6.5
+6.0
+5.5
+5.0
+4.5
+4.0
+3.5
+3.0
+2.5
+2.0
+1.5
+1.0
+0.5
0.0
–0.5
–1.0
–1.5
–2.0
1H
2H
<Heating operation>
TA-Tsc
[˚C]
0
A
–0.5
–1.0
B
–1.5
–2.0
–2.5
–3.0
–4.0
–5.0
–6.0
–7.0
–8.0
C
–9.0
–10.0
–11.0
Operation flow and applicable data, etc.
speed
3H
4H
time
→ Time Compressor
30 minutes
A
B
C
– 61 –
<Cooling operation>
1) The indoor fan speed is controlled
between W6 and W3.
The compressor speed in control
as shown in the left figure.
2) The set temperature increased
0.5°C per hour up to 2°C starting
Fan
Time
from the set temperature when
correction
SLEEP MODE has been received.
W6
W5
+ 1
zone
W4
W3
± 0
–1
zone
(min 1)
<Heating operation>
1) The indoor fan speed is controlled
within (W7) as maximum value.
speed
2) The louver position is set
0Hz
horizontally (Standard cooling
position) when the room
temperature comes close to the
set temperature or when 25
minutes passed after starting
A zone

SLEEP MODE operation.

B zone
C zone