<Cooling> (Continued)
Temperature
No. of
condition
operating
units
Indoor
Outdoor
5 units
27 / 19
35 / —
NOTES :
1. Measure surface temperature of heat exchanger pipe around of heat exchanger path U bent. (Thermistor thermometer)
2. Connecting piping condition : 5 meters × 5 units (5m/each indoor unit)
Standard
Indoor unit
pressure
A
B
C
D
E
P (MPa)
07
07
07
07
07
1.0 to 1.2
10
07
07
07
07
1.0 to 1.2
13
07
07
07
07
1.0 to 1.2
16
07
07
07
07
1.0 to 1.2
18
07
07
07
07
1.0 to 1.2
10
10
07
07
07
1.0 to 1.2
13
10
07
07
07
1.0 to 1.2
16
10
07
07
07
1.0 to 1.2
18
10
07
07
07
1.0 to 1.2
13
13
07
07
07
1.0 to 1.2
16
13
07
07
07
1.0 to 1.2
18
13
07
07
07
1.0 to 1.2
16
16
07
07
07
1.0 to 1.2
18
16
07
07
07
1.0 to 1.2
10
10
10
07
07
1.0 to 1.2
13
10
10
07
07
1.0 to 1.2
13
13
10
07
07
1.0 to 1.2
16
10
10
07
07
1.0 to 1.2
18
10
10
07
07
1.0 to 1.2
13
13
13
07
07
1.0 to 1.2
16
13
13
07
07
1.0 to 1.2
18
13
13
07
07
1.0 to 1.2
16
16
10
07
07
1.0 to 1.2
18
16
10
07
07
1.0 to 1.2
18
13
13
07
07
1.0 to 1.2
16
16
13
07
07
1.0 to 1.2
18
16
13
07
07
1.0 to 1.2
10
10
10
10
07
1.0 to 1.2
13
10
10
10
07
1.0 to 1.2
16
10
10
10
07
1.0 to 1.2
13
13
10
10
07
1.0 to 1.2
16
13
10
10
07
1.0 to 1.2
16
16
10
10
07
1.0 to 1.2
13
13
13
10
07
1.0 to 1.2
16
13
13
10
07
1.0 to 1.2
13
13
13
13
07
1.0 to 1.2
16
13
13
13
07
1.0 to 1.2
16
16
13
13
07
1.0 to 1.2
10
10
10
10
10
1.0 to 1.2
13
10
10
10
10
1.0 to 1.2
16
10
10
10
10
1.0 to 1.2
18
10
10
10
10
1.0 to 1.2
13
13
10
10
10
1.0 to 1.2
16
13
10
10
10
1.0 to 1.2
18
13
10
10
10
1.0 to 1.2
16
16
10
10
10
1.0 to 1.2
13
13
13
10
10
1.0 to 1.2
16
13
13
10
10
1.0 to 1.2
18
13
13
10
10
1.0 to 1.2
16
16
13
10
10
1.0 to 1.2
13
13
13
13
10
1.0 to 1.2
16
13
13
13
10
1.0 to 1.2
18
13
13
13
10
1.0 to 1.2
16
16
13
13
10
1.0 to 1.2
13
13
13
13
13
1.0 to 1.2
16
13
13
13
13
1.0 to 1.2
– 42 –
Heat exchanger
pipe temperature
Indoor
fan
T1 (°C)
T2 (°C)
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
15 to 17
51 to 53
High
Compressor
Outdoor
revolution
fan
(rps)
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65
High
65