No.
Part name
1. Reactor to be attached to the inverter
Replacement
7
of reactor
assembly
1) Perform works of Detachment 1 of
2) Remove the relay connector of the reactor.
3) Remove the reactor cover.
4) Remove the reactor. (ST1T Ø4 × 6, 2 pcs.)
5) Mount a new reactor.
2. Reactor to be attached to the partition
plate
1) Perform works of Detachment 1 of
2) Remove the reactor from the partition plate.
3) Mount a new reactor.
Caution to mount the inverter assembly.
Procedure
4
.
(Truss head B tight screw Ø4 × 6, 4 pcs.)
.
4
(ST1T Ø4 × 8, 2 pcs.)
When mounting the inverter assembly to the
partition plate, be sure to attach the hooks
certainly.
Hooks
– 133 –
Remarks
Reactor cover
1
and
Reactor cover
Partition plate
and
1
Partition
plate
Reactor
relay connector
Reactor
Reactor