Toshiba RAS-M10PKVP-E Service Manual page 116

Air-conditioner split type, hfc 410a
Hide thumbs Also See for RAS-M10PKVP-E:
Table of Contents

Advertisement

11-8-2. P.C. Board Layout
DB01
[1] Sensor characteristic table
100
90
80
70
60
50
40
30
20
10
0
0
10
20
+12V
L01
C03
TD
TA, TC, TCj, TO, TE, TS, TGa to TGe
30
40
50
Temperature (˚C)
– 116 –
+5V
GND
IC801
T101
TD
: Discharge temp. sensor
TA
: Room temp. sensor
TC, TCj
: Heat exchanger temp. sensor
TO
: Outdoor temp. sensor
TE
: Outdoor heat exchanger temp. sensor
TS
: Suction temp. sensor
TGa to TGe : Gas side temp. sensor