Warning Messages - Sony SRW-5800 Operation Manual

Hd digital videocassette recorder
Hide thumbs Also See for SRW-5800:
Table of Contents

Advertisement

Item number
Display
10
DEW DETECTED
11
TAPE TOP/END SENSOR
12
TAPE TOP SENSOR TROUBLE
13
TAPE END SENSOR TROUBLE
14
FAN MOTOR TROUBLE
20
CASSETTE COMPARTMENT
MOTOR LOCK
21
REEL SHIFT MOTOR LOCK
22
REEL POSITION SENSOR
TROUBLE
23
THREADING RING POSITION
ERROR
24
DT HARD ERROR
26
POWER SUPPLY UNIT TROUBLE
93
DR INTERFACE ERROR
97
NVRAM CHECK SUM ERROR
FF
SV UNDEFINED ERROR
A0
SYS UNDEFINED ERROR
A2
SYS1 - SYS2 DP-RAM ERROR
A5
SYS - FC DP-RAM ERROR
A8
SYS NV-RAM CHECK SUM ERROR
B3
XXX PLDX INITIAL ERROR
B8
SYS1 - SYS2 INTERFACE ERROR
B9
SYS - SV INTERFACE ERROR
BA
SYS - EQ INTERFACE ERROR
BB
SYS - FC INTERFACE ERROR
BC
SYS - 50PIN INTERFACE ERROR

Warning Messages

When one of the problems described below is detected, a
warning mark is displayed in the upper left corner of the
display. Operation can continue even when the mark is
flashing.
If you press the SFT button (see page 19) and the DIAG
button (see page 17) when the mark is flashing, an
information display appears, showing a warning message.
150
Error Messages/Warning Messages/Condition Messages
Meaning
Condensation was detected.
The tape beginning and tape end were detected at the same time.
A tape beginning sensor fault was detected.
A tape end sensor fault was detected.
A cooling fan motor operation fault was detected.
A fault was detected in a cassette compartment raising or lowering
operation.
A fault was detected movement of the reel table to adjust for
cassette size.
The reel table was detected in the L cassette position and S
cassette position at the same time.
The threading end and unthreading end were detected at the same
time.
A fault was detected in DT mechanism.
A fault was detected in the power supply unit.
A communications error between the SV CPU (board SS-102) and
drum CPU (board DR-508) was detected.
An operation fault was detected in the servo system NV-RAM
(board DR-508).
Undefined SV error was detected.
Undefined SY error was detected.
A DPRAM (board SS-102) operation fault between SYS1 and
SYS2 was detected.
A DPRAM (board FC-91 or FC-111) operation fault between SYS1
and FC was detected.
A SYS NVRAM (board SS-102) operation fault was detected.
An initialization error in the PLD was detected.
Note
The description of "XXX" at the beginning of the message and of
"X" immediately after the "PLD" depends on the PLD where the
error was detected.
Display example: SYS PLD1 INITIAL ERROR
A SYS CPU communications fault was detected.
An SV CPU communications fault was detected.
An EQ CPU communications fault was detected.
An FC CPU communications fault was detected.
A communications fault with the 50-pin CPU was detected.
Note
The warning messages can be viewed in any menu except
the CUE or SET UP menu.