3) Check the wiring through ZCT on the IDLE
CONTROL UNIT .
Make sure that an output wire from main
coil is passing through the ZCT on the IDLE
CONTROL UNIT .
4) Checking the IDLE CONTROL UNIT Check
the resistance between five leads of IDLE
CONTROL UNIT with circuit tester .
5
1
Terminal number of
the IDEL CONTROL UNIT
Circuit.tester..
(with.battery.power.source.1.5.V)
Apply.red.⊕.needle.
of.the.circuit.tester
NOTE : T he resistance readings vary depending on the types of circuit testers. The above
table shows an example of the resistance readings measured by an ordina,y analogue
circuit tester with I . 5 volt battery power source. It is advisable for you to check the
resistance readings using your standard circuit tester and revise the checking table.
4
2
3
①
②
③
④
⑤
IDEL CONTROL UNIT
OUTPUT WIRE
Apply.black.⊖.needle.of.the.circuit.tester
①
②
∞
-
∞
-
∞
250kΩ
∞
250kΩ
∞
8 .5kΩ
- 25 -
ZCT
CIRCUIT TESTER
(Resistance)
③
④
250kΩ
250kΩ
∞
∞
-
250kΩ
250kΩ
-
7 .8kΩ
7 .8kΩ
⑤
75kΩ
∞
75kΩ
75kΩ
-