Care Of Your Arriva 752 - Rinnai Arriva 752 Operation Manual

Fireplace
Hide thumbs Also See for Arriva 752:
Table of Contents

Advertisement

Care of your Arriva 752

your heater needs very little maintenance, however the following information will keep it
looking good and working efficiently.
Important
Switch off the appliance before
cleaning, DO NOT attempt
to clean the heater while it is
operating or hot.
DO NOT use solvents, all parts
of the heater and remote can be
cleaned using a soft damp cloth
and mild detergent.
About the filters
The filters of this appliance are
located inside the room air return
doors (side louvres) and consist of
two metal mesh strips.
Filters are located
inside the Room Air
Return doors
The build up of dust on the
filters reduce air flow through
to the heater. This reduces the
heater's efficiency and can lead
to the appliance shutting down.
Regular filter cleaning during the
heating season will stop this from
happening.
Cleaning the filters
Clean any dust or debris from both
sides of the filters using a vacuum
cleaner, a soft dry cloth, or a soft
brush. NEvER attempt to clean the
filters with water.
Heater shutdown due to filter
blockages
Do not wait for the blockage
indicator (error code 14) to come
on before cleaning the filters. Do
not continue to use the heater
once this indicator is flashing red.
when a build up is detected the
blockage indicator LED, located
above the receiver window, will
begin to flash red to let you know
there is a problem.
Once the indicator light is flashing,
if no action is taken, the heater
will eventually shut down to avoid
overheating. Error code 14 will
be displayed in the error display
window on the control panel of
the unit.
Returning the appliance to
normal after a shutdown
To restore normal operation after a
filter blockage:
1. Press the On/Off button once
to turn off the heater.
2. Clean the filters.
3. Press the On/Off button to
turn the heater back on.
4. use remote control to resume
normal operation.
Lower louvres
It is important that the warm air
discharge louvres are kept clear of
any obstructions as this will affect
the performance of the heater.
when an obstruction is detected
the blockage indicator LED (above
receiver window) will go red and
the heater will turn down to low
operation (front burner only). To
restore normal operation, remove
the obstruction and use the
remote control to resume normal
heater operation.