Appliance must be installed with an approved Rinnai flue system.
Appliance must be installed, commissioned and serviced by a licensed tradesperson
in accordance with these instructions and all applicable local rules and
regulations.
Owner, please retain this manual for future reference.
Arriva Operation and

Installation Manual

®
Approved by the Asthma and
Respiratory Foundation
SENSITIVE
CHOICE
SUPP OR T IN G
A S T H M A CA RE

Advertisement

Table of Contents
loading

Summary of Contents for Rinnai Arriva

  • Page 1: Installation Manual

    SUPP OR T IN G A S T H M A CA RE Appliance must be installed with an approved Rinnai flue system. Appliance must be installed, commissioned and serviced by a licensed tradesperson in accordance with these instructions and all applicable local rules and regulations.
  • Page 2: Limited Warranty

    3 below, rinnai new Zealand Limited supervising gas fitter’s registration number (“Rinnai”) will, at its own discretion, either and the gas fitting certification number. replace or repair any defective product at 4. This warranty commences from the date of no charge to the customer.
  • Page 3: Table Of Contents

    Front Fascia and Top Panel Wiring diagrams Commissioning Checklist Installer details Customer Contacts WARNING Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or loss of life. For assistance or additional information contact Rinnai on 0800 RINNAI (0800 746 624).
  • Page 4: About Your Arriva

    The operation section of this manual has been written to: • Highlight the safe operation and positioning of this appliance • Advise on maintenance, servicing and troubleshooting to ensure optimum performance rinnai new Zealand Limited Arriva Operation and Installation Manual: 10343-E 05-10...
  • Page 5: Safety

    Zealand Limited Arriva Operation and Installation Manual: 10343-E 05-10...
  • Page 6: Clearances

    This may be amplified if the air contains cooking vapours or cigarette smoke. To avoid this occurring, it is recommended that a mat be placed in front of the appliance. rinnai new Zealand Limited Arriva Operation and Installation Manual: 10343-E 05-10...
  • Page 7: Mantles And Surrounds

    25 mm. For additional depth, 25 mm of horizontal clearance is required for every 25 mm of added depth. Refer surround diagram below. Angled for free flow clearance for room air return rinnai new Zealand Limited Arriva Operation and Installation Manual: 10343-E 05-10...
  • Page 8: General Information

    If the supply cord is damaged and requires replacing, it must be replaced by a licensed tradesperson. This must be a genuine replacement part available from Rinnai. Hearths A hearth is not necessary but can be used for decorative purposes or protection of sensitive flooring if required.
  • Page 9: Remote Control

    Arriva has a fan that distributes warm air at a low level, this pushes the heat out and around the room as opposed to straight up. The Arriva also has a power flue that has virtually zero clearance to any cavity in which it is installed.
  • Page 10: Basic Heater Operation

    As a result the combustion fan about ignition starts several seconds before there are any signs of the Arriva starting. The normal ignition sequence is: 1. When the On/Off button is pressed the LED will glow red and the combustion fan starts to purge the system.
  • Page 11 Should the room temperature exceed 40 °C while the flame function is activated, the heater will switch off automatically. This is a safety feature. rinnai new Zealand Limited Arriva Operation and Installation Manual: 10343-E 05-10...
  • Page 12: Operation Using Remote Control

    L (Low) continuous combustion on low • 16 °C ~ 26 °C (in 1 °C steps) combustion rate varies to maintain selected temperature • H (High) continuous combustion on high rinnai new Zealand Limited Arriva Operation and Installation Manual: 10343-E 05-10...
  • Page 13 To turn the timers off, press the relevant timer button again. The heater will return to standby mode. If there are no timers set the Timer indicator will go out. After battery replacement the clock and timers may need to be re-programmed. rinnai new Zealand Limited Arriva Operation and Installation Manual: 10343-E 05-10...
  • Page 14 Standby only. Temperature Time Clock The remote control will show ‘Lock. Timer 1 Set ON OFF Timer 2 Set ON OFF To cancel, hold the Lock button for 3 seconds. rinnai new Zealand Limited Arriva Operation and Installation Manual: 10343-E 05-10...
  • Page 15: Care And Maintenance

    Clean any dust or debris from both sides of the filters using a vacuum strips cleaner, a soft dry cloth or a soft brush. NEVER attempt to clean the filters with water. rinnai new Zealand Limited Arriva Operation and Installation Manual: 10343-E 05-10...
  • Page 16 2. Clean the filters as outlined in these instructions. 3. Press the On/Off button to turn the heater back on. 4. Use remote control to resume normal operation. rinnai new Zealand Limited Arriva Operation and Installation Manual: 10343-E 05-10...
  • Page 17: Servicing

    Rinnai has a service and spare parts network with personnel who are fully trained and equipped to give the best advice on your Rinnai appliance. If your appliance needs servicing, please call Rinnai (0800 746 624) from a land line and select option 1 for a service centre in your area.
  • Page 18: Abnormal Flame Pattern

    Abnormal Flame Pattern Each Rinnai Flame Fire has a distinct flame pattern. This should look the same every time you start your fire, after an initial warm up period of approximately 20 minutes. Abnormal flame performance and/or pattern can indicate a problem with your fire, such as blocked gas injectors or artificial logs/burn media have shifted from when the fire was first installed.
  • Page 19: Troubleshooting

    Arriva are a normal part of operation. If you are still unsure or concerned after reading this section, please contact Rinnai. Ignition may not occur the first time it is operated due to air in the gas Using the pipes.
  • Page 20 Flat batteries replace remote  control batteries remote control Press the Standby/On  lock-up due to button signal being out or range, incorrectly aimed or obstructed rinnai new Zealand Limited Arriva Operation and Installation Manual: 10343-E 05-10...
  • Page 21: Error Codes

    Your Arriva heater is fitted with self diagnostic electronics that monitor the appliance during start up and operation. Should a fault occur the heater will shut down. The fault that has caused the shut down will be indicated by a pair of flashing digits in the error display window and a green flashing operation indicator.
  • Page 22: Arriva Accessories

    Arriva Accessories Rinnai offers 4 distinctly styled fronts. These interchangeable fronts allow the Arriva to be tailored to suit the style of your interior. A continuous sweep of curved glass. Arriva Plasma Fascia Arriva Midnight A continuous arc of glossy black glass.
  • Page 23: Installer Information

    Read these instructions to get an overview of the steps required before starting the installation. Failure to follow these instructions could cause a malfunction of the appliance. This could result in serious injury and property damage. rinnai new Zealand Limited Arriva Operation and Installation Manual: 10343-E 05-10...
  • Page 24 Balanced flue, inner = 50 mm, outer 75 mm Flue must be terminated to the atmosphere in accordance with NZS 5261. Rinnai warranty conditions will be voided if non Rinnai flue components are fitted. This heater is only certified for use with approved Rinnai Arriva flueing components.
  • Page 25: Appliance Positioning

    In some cases curtains may need restraining. the rinnai Arriva has a cool outer casing, it can be installed into an existing Enclosure masonry or decorative fireplace.
  • Page 26: Gas Supply And Direct Flue Wall Penetrations

    Direct flue Centreline of enclosure installations, where the flue terminal is to be terminated directly to the rear of the appliance. Gas supply penetration Ø 85~95 rinnai new Zealand Limited Arriva Operation and Installation Manual: 10343-E 05-10...
  • Page 27: Flueing

    Flueing - General For all installations an Rinnai Arriva flue system MUST BE used. Flue system must be fully assembled and secured in place before the heater is installed. IMPORTANT Must be compliant with ‘Clearances Required for Flue Flue terminal Terminals’...
  • Page 28 Flueing - Types of Flue Installations Refer Flue Installation manual provided with the Arriva Direct and Adaption Flue kits for detailed flue installation instructions. NOTE Flue is run direct from appliance to the termination point either in a Direct flueing horizontal or vertical direction.
  • Page 29 Used to terminate flue pipe in Protection against hot flue gases horizontal flue terminations when when the flue terminates low to used with Arriva Adaption Flue Kit the ground. rinnai new Zealand Limited Arriva Operation and Installation Manual: 10343-E 05-10...
  • Page 30 500 mm to allow the flue pipe to clear the base of the appliance. Appliance needs to be down rated, refer data plate. rinnai new Zealand Limited Arriva Operation and Installation Manual: 10343-E 05-10...
  • Page 31: Arriva Installation

    4. Securely connect flexible gas connection to the gas pipe, testing all connections for gas leaks. 5. Replace right hand panel and secure screws into place. rinnai new Zealand Limited Arriva Operation and Installation Manual: 10343-E 05-10...
  • Page 32: Arriva Installation

    Failure to secure the flue system using the supplied clamps may result in a dangerous situation. Arriva Adaption Flue Kit Arriva Direct Flue Kit Clamp Direct A & B flues Clamp Flue pipe rinnai new Zealand Limited Arriva Operation and Installation Manual: 10343-E 05-10...
  • Page 33 Secure the heater body through these points using appropriate fixings. Mounting points Flue spigot and The Rinnai Arriva flueing system must be installed in accordance with the air inlet hose instructions supplied. Once the flue and air connections are secured slide the flue access panel Flue access back into position and fasten.
  • Page 34 Left hand top log bottom log 3. Place the rear main log into the combustion chamber on the rear location pins. rinnai new Zealand Limited Arriva Operation and Installation Manual: 10343-E 05-10...
  • Page 35: Installing The Log Set

    6. Place the left hand bottom log into the combustion chamber so it hides the flame sensor rod from view. Place the right hand bottom log on the opposite side. 7. Replace combustion chamber glass panel and secure in place with the 2 retaining screws. rinnai new Zealand Limited Arriva Operation and Installation Manual: 10343-E 05-10...
  • Page 36 Take care not to bunch the tape in the corners. 4. Press the On/Off button to check inlet pressure when all the burners start operating. rinnai new Zealand Limited Arriva Operation and Installation Manual: 10343-E 05-10...
  • Page 37: Commissioning

    10. Press the On/Off button to turn the heater off. 11. Commissioning is now complete. Remove manometer, replace test point screws and replace plastic control panel cover. rinnai new Zealand Limited Arriva Operation and Installation Manual: 10343-E 05-10...
  • Page 38: Setting Air Guide Vanes

    Repeatedly adjust the vanes more than 5 times as this may cause the metal to fracture and/or break • Attempt to adjust the air flow direction while the appliance is operating or still hot as this can result in a burn injury rinnai new Zealand Limited Arriva Operation and Installation Manual: 10343-E 05-10...
  • Page 39: Front Fascia And Top Panel

    Secure the fascia to the appliance body with 2 retaining screws through the front of the warm air discharge louvre. Installing the Push the top panel down into place and secure with screws provided. top panel rinnai new Zealand Limited Arriva Operation and Installation Manual: 10343-E 05-10...
  • Page 40: Wiring Diagrams

    Wiring diagram Mark Colour Black Blue gr/y Yellow - Green Stripe Grey Orange Purple White yellow rinnai new Zealand Limited Arriva Operation and Installation Manual: 10343-E 05-10...
  • Page 41 Pilot Burner FR1~4 Flame Rods 1~4 Front Burner remote Controller REARB Rear Burner Convection Fan REARB (L) Rear Burner Left Convection Fan Motor REARB(R) Rear Burner Right Sparker rinnai new Zealand Limited Arriva Operation and Installation Manual: 10343-E 05-10...
  • Page 42: Commissioning Checklist

    Appliance positioned in a suitable location? (i.e. clearances, combustibles etc.) Was a Rinnai approved flue system installed and is the flue drawing effectively? Down rated (if applicable) according to data plate instructions? Has specified gas pressures been checked and set?
  • Page 43: Installer Details

    Installer details Company name:______________________________________________________________ Installer name:_______________________________________________________________ Address:____________________________________________________________________ ___________________________________________________________________________ Phone:_______________________________ Mobile:______________________________ Certificate of Compliance number for installation:____________________________________ Signed:______________________________ Date:_______________________________ rinnai new Zealand Limited Arriva Operation and Installation Manual: 10343-E 05-10...
  • Page 44: Customer Contacts

    Consumers: 0800 RINNAI (746 624) Installers: 0800 TO RINNAI (86 746 624) Address: 105 Pavilion Drive, Airport Oaks, Mangere, Manukau PO Box 53177, Auckland Airport, Manukau 2150 Phone: (09) 257 3800 Fax: (09) 257 3899 Email: info@rinnai.co.nz Website: www.rinnai.co.nz...