Omron G9SP Series Reference Manual page 46

Safety controller
Hide thumbs Also See for G9SP Series:
Table of Contents

Advertisement

Logic Function Blocks
3-3-4
NAND
Basic Function
Diagram
General Description
Optional Input Setting
Truth Table
Truth Table for One-input
NAND Evaluation
Truth Table for Two-input
NAND Evaluation
Truth Table for Three-input
NAND Evaluation
Truth Table for Four-input
NAND Evaluation
24
A logical NAND of the input signals is output.
Default
A logical NAND of the input signals is output.
Up to eight input signals can be evaluated.
The number of inputs can be increased on In/Out Setting Tab Page in the
function block property dialog box.
Parameter
Number of inputs
Input 1
Output 1
0
1
1
0
0: OFF, 1: ON
Input 1
Input 2
Output 1
0
x
x
0
1
1
0: OFF, 1: ON, x: Either ON or OFF
Input 1
Input 2
Input 3
0
x
x
x
0
x
x
x
0
1
1
1
0: OFF, 1: ON, x: Either ON or OFF
Input 1
Input 2
Input 3
0
x
x
x
0
x
x
x
0
x
x
x
1
1
1
0: OFF, 1: ON, x: Either ON or OFF
Maximum Number of Inputs
Setting range
1 to 8
1
1
0
Output 1
1
1
1
0
Input 4
Output 1
x
1
x
1
x
1
0
1
1
0
Section 3-3
Default setting
2