Omron G3PX-220EH-CT10 Manual
Omron G3PX-220EH-CT10 Manual

Omron G3PX-220EH-CT10 Manual

Power controller
Hide thumbs Also See for G3PX-220EH-CT10:

Advertisement

Quick Links

Power Controller
Single-phase Models
EUN Series
AC Power Controller with Phase-control
System Allows Precise Temperature
Control
Models with Base-up and Soft-start
Functions Available
EH Series
Phase Control System Makes It
Possible to Detect Disconnection of
Heaters
EC Series
Optimum Device for Controlling Input
Power for Pure Metal Heater, and
Incorporates Overcurrent Detecting and
Single Heater Burnout Detecting
Functions
OMRON's unique design and carefully-selected
materials made it possible to produce a compact
and lightweight Power Controller.
Replaceable, easy-to-install Power Device Car-
tridge assures ease of maintenance.
Detecting component failures and operating errors.
On applying for UL, CSA.
Ordering Information
EUN Series
Phase
Applicable
load
Resistive load
Single
Heater
Note: 1. The base-up output with a 0-mA temperature controller output (i.e. the temperature controller is OFF) differs from that with a 4-mA
temperature controller output. Refer the Characteristics data on page 67.
2. When ordering, make sure that the rated voltage is 200/230 VAC because the 200/220-VAC G3PX exists as well.
Level indicator
Base-up function
(see note 1)
Yes
Yes
Soft-start time
Carry
current
Approx. 0.5 to
20 A
10 sec
10
40 A
60 A
G3PX
Rated
Model
voltage
100/110 VAC
G3PX-220EUN
200/230 VAC
G3PX-240EUN
(see note 2)
(see note 2)
G3PX-260EUN
1

Advertisement

Table of Contents
loading

Summary of Contents for Omron G3PX-220EH-CT10

  • Page 1 Power for Pure Metal Heater, and Incorporates Overcurrent Detecting and Single Heater Burnout Detecting Functions OMRON’s unique design and carefully-selected materials made it possible to produce a compact and lightweight Power Controller. Replaceable, easy-to-install Power Device Car- tridge assures ease of maintenance.
  • Page 2 (see note 1) detection detection 100/110 VAC 00/ 0 Single Resistive load 20 A G3PX-220EH-CT03 Heater G3PX-220EH-CT10 200/230 VAC 200/230 VAC (see note 3) 40 A G3PX-240EH-CT03 G3PX-240EH-CT10 60 A G3PX-260EH-CT03 G3PX-260EH-CT10 Yes (see note 2) 20 A...
  • Page 3: Specifications

    G3PX G3PX Specifications Ratings Control Item G3PX- G3PX- G3PX- G3PX- 220EUN/ 220EH/ 220EHN/ 220EC/ 240EUN/ 240EH/ 240EHN/ 240EC/ 260EUN 260EH 260EHN 260EC Rated voltage 100/110, 200/230 VAC Frequency 50/60 Hz (see note 1) Input External 2 kΩ (type B, 2 W min.) 3 kΩ...
  • Page 4 G3PX G3PX Item G3PX-220EUN/ G3PX-220EH/240EH/260EH G3PX-220EHN/ 240EUN/260EUN 240EHN/260EHN π Min. phase detection Approx. 1/6 π Min. phase setting Approx. 1/6 Min. load current for 30% max. of rated current ON error detecting (see note 5) Abnormality detection 0.1 s max. 1 s max.
  • Page 5: Engineering Data

    G3PX G3PX Engineering Data The following data is for an ambient temperature of 25 C. Output Characteristics Duty Setting G3PX-EUN/EH/EHN Models G3PX-EC G3PX-EUN/EH/EHN Models 100% Input current (mA) Input current (mA) Input current (mA) Base-up Characteristics G3PX-2 0EUN Models Input current (mA) Load Current vs.
  • Page 6 G3PX G3PX Withstand Inrush Current G3PX-220E Models G3PX-240E Models G3PX-260E Models Energizing time (ms) Energizing time (ms) Energizing time (ms) Note: The above are possible on condition that the G3PX is in non-repetitive operation. If the G3PX is in repetitive operation, reduce the applied current to half.
  • Page 7 G3PX G3PX Nomenclature Single-function Model Multiple Heater Burnout Detection (EUN-series Model) (EHN-series Model) G3PX-2 0EUN G3PX-2 0EHN-CT RUN/SET switch for setting condition for multiple heater burnout detection. Level indicator Level indicator RESET switch POWER indicator POWER indicator SHORT indicator (for short-mode BASE-UP adjuster failure detection) DUTY adjuster...
  • Page 8: Operation

    G3PX G3PX Operation Error Detecting Function Wiring Single-phase Models 2. When EH/EHN/EC-series models detect a short-mode failure, the SHORT indicator is lit and the SPDT relay output is All G3PX-2 0EH/EHN/EC-series models incorporate terminals 11 and 12 for the CT Unit, 13 and 14 for the external reset switch, and 16 and 17 for relay output as well as power/input terminals 1 through With continuous load current.
  • Page 9 *Impedance Load 2 Note: Two G3PX models can be connected in series to OMRON’s single Tempera- ture Controller (with an internal impedance of 600 Ω) with a current output. 2. A Temperature Controller with an output of 7 to 20 mA is used with the G3PX to change the duty.
  • Page 10 G3PX G3PX ON/OFF Control Single-phase Models 1. A Temperature Controller is used to change the duty of G3PZ. Load 1 Internal DUTY adjuster 5/12/24 VDC E5 S Tem- ON/OFF perature Controller – G3PX DUTY Load 2 G32X-V3K External DUTY Adjuster (3 kΩ) Note: You can change the duty with the external or internal variable resistor.
  • Page 11 G3PX G3PX Manual Control Single-phase Models Load 1 G32X-V3K or G32X-V2K External DUTY Adjuster Internal DUTY adjuster Note: Delicate duty adjustment is possi- ble with the external or internal re- sistor. G3PX G32X-V3K External DUTY Use a right DUTY adjuster (2- or Adjuster (3 kΩ) for duty set- 3-kΩ...
  • Page 12 G3PX G3PX 4. Set the RUN/SET switch to RUN. When all settings have been finished, the OPEN indicator is OFF. Note: 1. The G3PX can control any part of the phase as long as π the controlled phase is approximately 1/6 or more in width.
  • Page 13: Replacement Parts

    G3PX G3PX Replacement Parts G32X-A Power Device Cartridge The temperature indicator will be lit in red if the power element is damaged. If the power element is damaged due to overcurrent or other rea- sons, the power element and its peripheral parts can be replaced. The power element and its peripheral parts can be replaced without disconnecting the wires of the G3PX.
  • Page 14 G3PX G3PX 4. Loosen the screws on both corners. 3. Insert the Cartridge into the opening of the G3PX so that the letters on the Cartridge and those on the G3PX are in the same direction and sides A and B are even. Loosen Loosen 5.
  • Page 15 G3PX G3PX Dimensions Note: All units are in millimeters unless otherwise indicated. Single-phase Models G3PX-220E Series Mounting Holes Four, 4.5 dia. or M4 holes 140 0.3 50 0.3 Two, 4.6 dia. Two, M4 screws holes 140 0.2 109.8 150 max. Two, R2.3 holes 50 0.2...
  • Page 16 G3PX G3PX G3PX-260E Series Mounting Holes Four 4.5-dia. or M4 holes 140 0.3 80 0.3 Two, 4.6 dia. Two, M6 screws holes 140 0.2 109.8 150 max. Two, R2.3 holes 80 0.2 100 max. 130 max. G32X-CT03 Series 60 max. G32X-CT10 Series Mounting Holes...
  • Page 17: Installation

    G3PX G3PX Installation Terminal Arrangement Single-phase Models G3PX-220EUN G3PX-220EH G3PX-240EUN G3PX-240EH G3PX-260EUN G3PX-260EH CT UNIT G32X-CT External main setting 2 kΩB, 2 W for External main setting 3 kΩB 2 W EUN-series models 3 kΩB 2 W MAN SET MAN SET Voltage ON/OFF input Voltage ON/OFF input VOLTAGE IN...
  • Page 18: Correct Use

    Wiring Only resistive loads can be connected to the G3PX. Contact your Make sure that the lead wires are thick enough according to the cur- OMRON representatives if it is necessary to connect inductive or rent. transformer loads. Be sure to turn off power to the G3PX when wiring. The G3PX has...
  • Page 19 G3PX G3PX If any of the following models is used and the actual load current is Also check the current limit adjuster if the G3PX is a constant DC 50% of the maximum rated load current or lower, increase the num- model.
  • Page 20 G3PX G3PX When the supply current is 25% of the rated current, the wires The OPEN indicator of a multiple heater burnout detection model must be coiled three to four times on the CT Unit. is lit at the initial stage (G3PX-2 0EHN Series). No reset will be performed even if the RESET button is pressed.