Safety Device Function Blocks
3-5-6

Safety Gate Monitoring

Basic Function
Diagram
General Description
Startup
3. When the workpiece moves to the right until it is no longer detected by the
MS12, the muting status set for the Override will be cleared, and the Over-
ride Status will go OFF.
Note Muting Status
• ON during muting due to override function.
■ Timing Chart
Normal Operation of the Override Function (Muting Mode: Parallel Muting with
2 Sensors)
AOPD Input 1 (NC)
AOPD Input 2 (NC)
Override Input 1 (NO)
Override Input 2 (NO)
Muting Signal 11
Muting Signal 12
Output Enable
Muting Status
Override Status
Fault Present
Monitors the status of a safety gate (i.e., a safety door switch or safety limit
switch). Function tests can be set for Safety Category 2.
Default
The Safety Gate Monitoring function block monitors the status of a safety
gate. Safety gate status is monitored using an input signal from a safety door
switch or safety limit switch connected to the door.
The Output Enable signal will turn ON if the input from the switch being moni-
tored is active. The Output Enable signal will turn OFF if the input is inactive or
if an error is detected for the function block.
All errors are turned OFF and all timers are reset at the start of operation.
Outputs are turned ON or OFF according to the input status.
Refer to information later in this section if the function test has been enabled.
Override Discrepancy Time
Maximum Number of I/O
Section 3-5
All muting signals are OFF
65