8.
Press
to re-enter Primary zone adjustment.
Siren chirps 2 times.
Primary zone can now be re-adjusted as described in #4.
Or press
The siren will chirp 3 times when sensor adjustment mode has been exited.
N N o o t t e e : : You must wait 15 seconds for omnisensor to become active after arming.

troubleshooting

Sensors do not trigger the alarm.
Has the FACT II system been triggered? To check this, turn the ignition key on
and off to clear the FACT II from memory, and then retest the shock sensor. For
a detailed description of FACT II, see the FACT II: False Alarm Control
Technology section of this guide.
Closing the door triggers the system, but opening the door does not.
Have you correctly identified the type of door switch system? This happens often
when the wrong door input has been used.
The system will not passively arm until it is remotely armed and then disarmed.
Are the door inputs connected? Is a BLUE wire connected to the door trigger wire
in the vehicle? The GREEN H1/9 or the VIOLET H1/8 should be used instead.
The PlainView 2 Valet switch does not work.
Is the quick disconnect plugged in correctly?
Is it plugged into the correct socket?
Check the System Features Learn Routine for the default PIN code.
Has the PIN code been changed?
The status LED does not work.
Make sure that it is plugged in. (See the Plug-In Harnesses section of this guide.)
Is the LED plugged into the correct socket?
Is the quick disconnect plugged in correctly?