remote adjustable proximity sensor
The proximity sensor input circuitry has been improved for G5 so the sensor only has
power when the alarm is armed. While driving this protects highly sensitive vehicle
electronics (i.e. radar detectors) that can be affected by outside interference. However,
this does change the way the sensor is adjusted but will not affect normal operation
of the sensor.
locating the proximity sensor
Inside the vehicle's headliner is the optimal mounting location for this sensor and
should always be the first choice. The sensor should face down, centered side to side,
with the wire harness exiting toward the front of the vehicle.
If headliner mounting is not possible, the sensor can be placed in a lower area of the
vehicle, but field size and sensitivity may be affected. The armrest of the center con-
sole may be appropriate.
N N O O T T E E : : Never place the sensor behind any metal brackets or under console pockets
that will have coins or other metal objects in it.
adjusting the proximity sensor
It is recommended that adjustments be performed away from fluorescent lighting,
large metal structures, or confined areas that can affect the sensor field. The proxim-
ity sensor field takes about one to two minutes to settle after it receives power. Make
the first adjustment with the remote control after about 45 seconds. If the alarm does
not see an adjustment signal, it will exit adjustment mode after 60 seconds. Make the
adjustments slowly to let the sensor field settle. Each zone has 32 settings that are indi-
cated by chirps that raise and lower in frequency as adjustments are made.
If the alarm exits adjustment mode automatically it will revert to its previous settings.
To lock in the new settings, you MUST exit using the
The total adjustment time for this sensor should be 5 minutes or less. Taking the time
to properly adjust this state-of-the-art sensor will give your customer years of unsur-
passed security and stop any returns for further adjustments.
1.
Disarm system
2.
Transmit Channel 16. (Press
The LED will turn on and the siren will chirp 1 time.
Primary (full trigger) zone adjustment has now been entered.
Primary zone can now be adjusted.
54
button after programming!
3 times then
1 time)