mounting the tilt sensor
The sensor control module must be mounted at an angle no greater than 45 degrees,
with respect to the horizontal plane of the vehicle, and it must be mounted with the
case top facing upward. We recommend mounting the control module to the floor of
the vehicle. To mount the control module, fasten the unit with either Velcro or screws.
TM
programming the sensor
The unit has 2 wire loops (one WHITE and the other BLACK) for setting both the tilt
threshold and the arming delay. The 2 wire loops are located on the side of the sen-
sor next to the harness plug.
tilt sensitivity threshold
The BLACK loop controls the tilt sensitivity threshold that detects when the vehicle is
being lifted. A 1-degree threshold is the default setting for extreme sensitivity. If the
BLACK loop is cut, then a 3-degree threshold is selected for normal sensitivity.
arming delay
The WHITE loop sets the amount of time the sensor waits before it will become active.
A 10-second delay is the default setting. If the WHITE loop is cut, then a 2-minute
delay is selected before becoming active.
© 2006 directed electronics—all rights reserved
WHITE LOOP
RED
ORANGE
BLUE (ZONE 3)
BLUE (ZONE 8)
SHOCK SENSOR PORT
BLACK LOOP
TILT SENSOR
504C SHOCK SENSOR
BLUE
BLUE
ORANGE
RED
OPTIONAL
53