Problem
urner will not light using knobs or
B
igniter.
Burner will not light using a match.
Sudden drop in gas flow or reduced
flame height.
Irregular flame pattern, flame does not
run the full length of burner.
Flame is yellow or orange.
GPF2414AE
Instruction Manual

Troubleshooting

Possible Cause
Wires and/or electrode covered with
cooking residue.
Electrode and burners are wet.
Electrode cracked or broken –
sparks at crack.
Wire loose or disconnected.
No gas flow.
Coupling nut and regulator not fully
connected.
Obstruction of gas flow.
Disengagement of burner to valve.
Spider webs or insect nest in venturi.
Burner ports clogged or blocked.
Tank out of gas.
Excess flow safety device may
have been activated.
Burner ports are clogged or blocked.
New burner may have residual
manufacturing oils.
Spider webs or insect nest in
venturi.
Food residue, grease or seasoning
salt on burner.
Poor alignment of valve to burner
venturi.
20
Prevention/Cure
Clean wire and /or electrode with
rubbing alcohol.
Wipe dry with cloth.
Replace electrode.
Reconnect wire or replace electrode/
wire assembly.
Check if propane tank is empty. If
empty, replace or refill. If propane
tank is not empty, refer to
Excessive flow safety valve
reset procedure on page 18.
Turn the coupling nut about
one-half to three quarters
additional turn until solid stop.
Tighten by hand ONLY - do not
use tools.
Clear burner tubes.
Check for bent or kinked hose.
Reengage burner and valve.
Clean venturi.
Clean burner ports.
Check for gas in propane tank.
Refer to the Excess flow safety valve
reset procedure on page 18.
Clean burner ports.
Burn grill for 15 minutes with the lid
closed.
Clean venturi.
Clean burner.
Assure burner venturi is properly
engaged with valve.

Advertisement