OPTIONAL FAN INSTALLATION
elecTrical insTallaTion To be done by a quali-
fied insTaller and must be connected and grounded in
accordance with local codes. In the absence of local codes,
use the current CSA C22.1 C
or the AnSI/nFPA 70
nAtionAl eleCtriCAl Code
States.
FIGURE 107
GD36 THERMOSTATIC SENSOR CONTROL
With the thermostatic sensor option, the fan, when turned
on, becomes thermally activated, and will automatically run
approximately 15-30 minutes after the fireplace has been lit
and for approximately 30-45 minutes after the fireplace has
been turned off.
Use of the fan increases the output of heat.
Unplug the power cord from the receptacle. Connect all wires
as shown.
FIGURE 109
AnAdiAn eleCtriCAl Code
in Canada
in the United
To safely install the fan, turn off the electricity first.
If the fireplace was not previously equipped with a fan:
route a grounded -wire, 60hz power cable to the junction box.
At this point, it must be strain
relieved and insulated.
The wire harness provided in this
kit is a universal harness. When
installed, ensure that any excess
wire is contained, preventing it
from making contact with moving
or hot objects.
To ease installation of the fan, remove the hinge screen
and valve control door (lower louvres) from the base of the
fireplace.
Position the vibration reducing pad into the clip and onto the
threaded stud at the other end, piercing a hole into the pad.
The fan assembly must be able to be positioned entirely onto
the pad.
Slide the fan assembly past the controls and into the clip.
Secure using the lock washer and nut provided.
Plug the harness cord into the receptacle.
This optional kit is meant to be used only in conjunction with
the GD65 Fan Kit, shown above, which may be ordered from
your Wolf Steel / Napoleon dealer.
Attach and secure the sensor assembly bracket to the secur-
ing stud located next to the receptacle/junction box at the
bottom left of the unit using the lock washer and wing nut.
Ensure that the thermodisc touches the firebox wall.
Plug the power cord back into the receptacle.
When installed, ensure that any excess wire is contained, pre-
venting it from making contact with moving or hot objects.
Adjust the pilot screw to provide properly sized flame. Turn
in a clockwise direction to reduce the gas flow.
5
FIGURE 108
FIGURE 110
W45-0566 / A / 07..06