Napoleon BGD36CFNTR Installation And Operating Instructions Manual page 10

Napoleon gas fireplaces - installation and operating instructions

Advertisement

0
BGD36CF
PERISCOPE TERMINATION
For optimum performance, it is recommended that
all horizontal runs have a 1 inch rise per foot.
When terminating vertically, the vertical rise is a mini-
mum 36 inches and a maximum 40 feet from the centre
of the fireplace flue outlet.
Use the GD0 periscope kit to locate the air termination
above grade. The periscope must be installed so that when
final grading is completed, the bottom air slot is located a mini-
mum of  inches above grade. The maximum allowable vent
length depends on the model of fireplace, as illustrated.
FIGURE 15
TOP EXIT INSTALLATION
TOP EXIT INSTALLATION
tOP eXIt INStALLAtION
BGD42CF
PERISCOPE TERMINATION
Use the GD40 periscope kit to locate the air termination
20" MAX
20" MAX
above grade. The periscope must be installed so that when
final grading is completed, the bottom air slot is located a
minimum of  inches above grade. The maximum allow-
able vent length depends on the fireplace, as illustrated.
24" MINIMUM
REGARDLESS
OF HORIZONTAL
VENT LENGTH
BELOW GRADE INSTALLATION
MAXIMUM 10FT VENT LENGTH
USE GD401 PERISCOPE KIT
W45-0566 / A / 07..06
SPECIAL VENT INSTALLATIONS
TOP EXIT INSTALLATION
FIGURE 16
FIGURES 4
20" MAX
FIGURES 4
REAR EXIT INSTALLATION
REAR EXIT INSTALLATION
ReAR eXIt INStALLAtION
12"MINIMUM
FIGURE 17
TOP EXIT INSTALLATION
CORNER TERMINATION
The maximum vent length for a corner installation is 0 inches
of horizontal run, in addition to the 45° offset. In this case zero
rise is acceptable when using rigid. See FIGURE 8. Flexible
venting must maintain a 6" rise. See FIGURE 9.
FIGURE 18
20" MAX
REAR EXIT INSTALLATION
FIGURE 19