Section 3: Installing The Fireplace; Step 1 Locating The Fireplace - Heat & Glo PIER-TVFL-IPI Owner's Manual

Table of Contents

Advertisement

Step 1
Locating the
Fireplace
Minimum Clearances from the Fireplace to
Glass
Sides
Floor
36 inches
0
(914 mm)
The diagram below shows space and clearance
requirements for locating a fireplace within a room.
GLASS
36"
PIER-TVFL-IPI
GLASS
TOP
VIEW
GLASS
ST-42TVFL-IPI
GLASS
Figure 3.
Fireplace Locations and Space
Requirements
Clearance Requirements
The top, back, and sides of the fireplace are
defined by stand-offs.
Combustible Materials
Back of
Metal Ends
Fireplace
of Fireplace
1/2 inch
1/2 inch
(13 mm)
(13 mm)
The clearance to the ceiling is measured from the top
of the unit, excluding any standoffs (see Step 10
Finishing).
The minimum clearance to a perpendicular wall
extending past the face of the fireplace is one inch
(25mm).
The metal end(s) of these fireplaces may NOT be
recessed into combustible construction.
Heat & Glo • PIER-TVFL, ST-42TVFL-IPI • 455-901 Rev. F • 8/05
GLASS
36"
36 "
36"
1"
36"
Top of
Fireplace
Ceiling
4-1/2 inches
36 inches
(114 mm)
(914 mm)
3