Heat & Glo ST-HV-IPI Owner's Manual

Heat & Glo ST-HV-IPI Owner's Manual

Installation and operation
Hide thumbs Also See for ST-HV-IPI:

Advertisement

Models:
Pier-HV-IPI
ST-HV-IPI
LCOR-HV-IPI
RCOR-HV-IPI
Important operating
and maintenance
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing proper-
ty damage, personal injury, or death.
• Do not store or use gasoline or other flamma-
ble vapors and liquids in the vicinity of this or
any other appliance.
• What to do if you smell gas
- Do not try to light any appliance
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed by
a qualified installer, service agency, or the gas
supplier.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must
be installed in accordance with the manufacturer's instruc-
tions and the manufactured home construction and safety
standard, Title 24 CFR, Part 3280 or Standard for Installa-
tion in Mobile Homes, CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas indi-
cated on the rating plate.
CAUTION
DO NOT DISCARD THIS MANUAL
Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08
Owner's Manual
Installation and Operation
Leave this manual with
party responsible for
use and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
DO NOT touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
• CAREFULLY SUPERVISE children in same room as fireplace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other flammable
materials.
• Keep clothing, furniture, draperies and other flammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fixed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
In the Commonwealth of Massachusetts installation must
be performed by a licensed plumber or gas fitter.
See Table of Contents for location of additional
Commonwealth of Massachusetts requirements.
Installation and service of this appliance should be
performed by qualified personnel. Hearth & Home
Technologies suggests NFI certified or factory-trained
professionals, or technicians supervised by an NFI
certified professional.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo ST-HV-IPI

  • Page 1 Mobile Homes, CAN/CSA Z240MH. professionals, or technicians supervised by an NFI This appliance is only for use with the type(s) of gas indi- certified professional. cated on the rating plate. Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 2: Safety And Warning Information

    DO NOT place furniture or any other combustible Young children should be CAREFULLY SUPERVISED household objects within 36 inches of the fireplace when they are in the same room as the appliance. front. Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 3: Table Of Contents

    Step 12. Lighting the Fireplace ..............44 After the Installation ..................44 Maintaining and Servicing Your Fireplace ........ 45 Contact Information ..................46 = Contains updated information. Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 4: Service Parts

    Pier-HV-IPI Service Parts Beginning Manufacturing Date: June 2003 Service Parts Diagram Ending Manufacturing Date: ______ Log Set Assembly Part number list on following page. Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 5: Service Parts List

    Conversion Kit NG LPK-MS Conversion Kit LP Pilot Orifice NG 446-505 Pilot Orifice LP 446-517 Regulator NG NGK-DXV Regulator LP LPK-DXV Additional service part numbers appear on following page. Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 6: Approvals And Codes

    These models may be installed in a bedroom or bed-sitting room in the U.S.A. and Canada. Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 7: Requirements For The Commonwealth Of Massachusetts

    (1/2) inch in size, “GAS See Gas Connection section for additional Common- VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OB- wealth of Massachusetts requirements. STRUCTIONS”. Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 8: Getting Started

    Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 9 (121mm) TOP VENT COLLARS TOP STANDOFFS REAR VENT COLLARS SIDE GLASS GAS CONTROLS DOOR & LABELS GAS LINE ACCESS ELECTRICAL ACCESS Figure 1. Diagram of the PIER-HV-IPI Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 10 (114mm) TOP VENT COLLARS TOP STANDOFFS REAR VENT COLLARS GAS CONTROLS SIDE GLASS & LABELS DOOR GAS LINE ACCESS ELECTRICAL ACCESS Figure 2. Diagram of the ST-HV-IPI Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 11 COLLARS REAR VENT COLLARS SIDE GLASS DOOR END GLASS GAS LINE DOOR ACCESS GAS CONTROLS & LABELS ELECTRICAL ACCESS Figure 3. Diagram of the LCOR-HV-IPI and RCOR-HV-IPI Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 12: Installing The Fireplace

    The minimum clearance to a perpendicular wall extending past the face of the fireplace is one inch (25 mm). The metal ends of the fireplace may NOT be recessed into combustible construction. Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 13: Step 2. Framing The Fireplace

    Bottom ......1/2 ....13 Sides ......... 1 ....25 For minimum clearances, see the direct vent termination clearance diagrams on pages 31 and 32 in this manual. Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 14 L & R-COR-HV-IPI ST-HV-IPI Model PIER-HV-IPI 42-1/8 42-1/2 35-3/4 ST-HV-IPI 47-5/8 42-1/2 35-3/4 L&RCOR-HV-IPI 42-1/8 42-1/2 28-3/4 35-3/4 NOTE: DIMENSIONS SHOWN IN INCHES Figure 5. Framing Dimensions Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 15 DVP48 8-9/16 1/2 TYP 12-9/16 NOTE: PIPES OVERLAP 1-1/4 INCHES AT EACH JOINT. Figure 6. DVP-Series Direct Vent Component Specifications (5-inch inner pipe / 8-inch outer pipe) Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 16: Step 3. Installing The Vent System

    PVK-80 DVP-TV DVP-TRAP DVP-TB1 DVP-TVHW (Required to have a minimum of 3 feet of vertical in the vent system) Figure 7. Vent System Components and Termination Kits Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 17 Figure 9 2. Break the Flue Restrictor into two pieces. Do this by bending the part back and forth until it breaks Figure 12. (see Figure 10). Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 18 6’ MIN. (1.83m) 12' MAX. (3.6m) V + H = 50’ MAX. (15.2m) V + H = 50’ MAX. (15.2m) Figure 14. Venting with One 90° Elbow Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 19 5’ MIN. (1.5m) 10' MAX. (3.0m) 6’ MIN. (1.83m) 12' MAX. (3.6m) V + V + H = 50’ MAX. (15.2m) Figure 15. Venting with Two 90° Elbows Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 20 V + H + H = 50’ MAX. (15.2m) H + H = 18’ MAX. (5.5m) H + H = 12’ MAX. (3.6m) Figure 17. Venting with Two 90° Elbows Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 21 + H + H = 50’ MAX. (15.2m) H + H = 18’ MAX. (5.5m) H + H = 12’ MAX. (3.6m) Figure 18. Venting with three 90° elbows Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 22 12' MAX. (3.6m) + H + H = 50’ MAX. (15.2m) V+ V H + H = 12’ MAX. (3.6m) Figure 19. Venting with three 90° elbows Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 23: Installing Vent Components

    If the installation is for a termination cap attached directly to the fireplace, skip to the sections, Install Firestops and Vent Termination. ELBOW ELBOW SEAM FRONT VIEW Figure 21 TOP VIEW Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 24 HOLE INTERIOR WALL SHIELD EXISTING CEILING JOISTS FRAMING MEMBERS CEILING 12" Figure 25 Hole & New Framing Members Figure 23. 10" x 12" Hole and Vent Pipe Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 25: Vent Termination

    NOTE: There must be NO INSULATION or other combustibles inside the framed firestop opening. NAILS (4 REQUIRED) RAFTER 7 1/4" (184mm) Figure 28. Trapezoid Termination Cap CEILING CEILING FIRESTOP Figure 27. Attic Firestop Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 26 Figure 29. Vent Termination Minimum Clearances CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED. Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 27 12/12 to 14/12 over 14/12 to 16/12 over 16/12 to 18/12 over 18/12 to 20/12 over 20/12 to 21/12 Figure 30. Minimum Height from Roof to Lowest Discharge Opening Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 28: Step 4. Positioning, Leveling, And Securing The Fireplace

    • Secure the fireplace to the framing by nailing or screwing. • Holes are provided in the base pan for securing the unit to the floor. Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 29: Step 6. The Gas Supply Line

    • At the gas line access hole the gap between the supply piping and gas access hole can be plugged with non- combustible insulation to prevent cold air infiltration. Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 30: Step 8. Wiring The Fireplace

    • Uninterrupted or continuous power is required at all times in IPI system EXCEPT when using battery back-up. • Incorrect wiring will override IPI safety lockout and may cause explosion. Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 31: Wall Switch

    This will provide the best air flow (see Figure 36). the fireplace as the vent collars are on. This will provide the best air flow (see Figure 37). Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 32 SWITCH MINIMUM 14-3 AWG WITH GROUND Black Black White White Green Green JUNCTION BOX POWER SUPPLY WIRES SWITCH BOX Figure 38. Junction Box Wired to Wall Switch Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 33: Step 9. Finishing

    14” 13” 12” HOOD NOTE: 12” mantel at 23” above hood. Minimum Vertical and Maximum Horizontal Figure 40. Dimensions of Combustibles above Fireplace Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 34: Step 10. Installing Trim, Logs & Ember Material

    Some local building codes require the use of tempered glass with permanent marking in such locations. Glass meeting this requirement is available from the factory. Please con- tact your dealer or distributor to order. Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 35 The ember bed is now complete (see Figure 49.) (teco-sil). Figure 49. Figure 46. Turn on the electric ember lights and paint the glass to a darkness as desired (see Figure 47). Figure 47. Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 36: Placing The Ember Material

    Any skin oils which get on a new bulb will greatly shorten the life of the bulb. The bulb can be cleaned with isopropyl alcohol (see Figure 53). Figure 53 Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 37: Step 11. Before Lighting The Fireplace

    This will help avoid setting off smoke detectors, and help eliminate any odors associated with the fireplace’s initial burning. Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 38: Maintaining And Servicing Your Fireplace

    Make sure the flames are steady - not lifting or floating. See Figure 54. The flame sensor (IPI) tip should be covered with flame. See Figure 32. Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...
  • Page 39: Contact Information

    6748942, 6769426, 6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending. Printed in U.S.A. - Copyright 2008 Heat & Glo • PIER-HV-IPI, ST-HV-IPI, L&R-COR-HV-IPI • 2005-900 Rev. M • 9/08...

This manual is also suitable for:

Pier-hv-ipiRcor-hv-ipiLcor-hv-ipi

Table of Contents