Heat & Glo PIER-40 Owner's Manual

Multi-sided wood burning fireplace
Hide thumbs Also See for PIER-40:
Table of Contents

Advertisement

Models:
BAY-40, PIER-40
Multi-Sided
Wood Burning Fireplace
Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING
If the information in these instruc-
tions is not followed exactly, a
fi re may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• Do not overfi re. Overfi ring will void your
warranty.
• Comply with all minimum clearances to
combustibles as specifi ed. Failure to
comply may cause house fi re.
WARNING
Fire Risk
For use with solid wood fuel or decorative
gas appliance only.
DO NOT install unvented gas logs.
BAY-40 Shown
NOTICE
DO NOT DISCARD THIS MANUAL
Read, understand
and follow these
instructions for safe
i n s t a l l a t i o n a n d
operation.
Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08
Owner's Manual
Installation and Operation
Leave this manual with
party responsible for
use and operation.
WARNING
Hot screen/mesh and glass doors will cause burns.
DO NOT touch screen/mesh or glass doors until
cooled
NEVER allow children to touch screen/mesh or glass
doors
Keep children away
CAREFULLY SUPERVISE children in same room as
fi replace.
Alert children and adults to hazards of high
temperatures.
High temperatures may ignite clothing or other
fl ammable materials.
Keep clothing, furniture, draperies and other
fl ammable materials away.
Installation and service of this fi replace
should be performed by qualifi ed personnel.
Hearth & Home Technologies suggests NFI
certifi ed or factory-trained professionals, or
technicians supervised by an
NFI certifi ed professional.
HOT SURFACES!
Screen/mesh, glass doors
and other surfaces are hot
during operation AND cool
down.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo PIER-40

  • Page 1 For use with solid wood fuel or decorative gas appliance only. • DO NOT install unvented gas logs. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 BAY-40 Shown NOTICE DO NOT DISCARD THIS MANUAL •...
  • Page 2: Congratulations

    OPEN OR CLOSED ONLY. WHEN BURNING A DECORATIVE GAS APPLIANCE IN THE FIREPLACE, ADJUST DAMPER TO THE FULLY OPEN POSITION. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 Congratulations! This owner’s manual should be retained for future refer- ence.
  • Page 3: Table Of Contents

    Framing & Clearances A. Select Fireplace Location B. Clearances C. Sidewalls/Surrounds D. Frame the Fireplace Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 Table of Contents Installation of Fireplace A. Things to Consider B. Position the Fireplace C.
  • Page 4: Limited Warranty

    Adjustments, regular maintenance, cleaning and temporary repairs, or the failure to duplicate the problem in the home is not covered under this warranty. 4021-645A 09-01-08 Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 Wood Pellet...
  • Page 5 If warranty service is needed, you should contact your installing dealer. If the installing dealer is unable to provide necessary parts or components, contact the nearest authorized HHT dealer or supplier. 4021-645A 09-01-08 Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 Page 2 of 2...
  • Page 6: Listing And Code Approvals

    NOTICE: This fireplace is tested and approved as a decorative fi replace. It should not be factored as a primary heat source in residential heating calculations. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 B. Non-Combustible Materials •...
  • Page 7: User Guide

    Section 2.D. Section 2.E. Wood Fuel Section 2.M. Hearth Figure 2.1 General Operating Parts Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 User Guide WARNING Damper Control Up - Open Down - Closed Glass Doors (not shown) Section 2.H.
  • Page 8: Seasoned Wood

    CAUTION! Odors and vapors released during initial operation may be irritating to sensitive individuals. Open windows for air circulation. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 D. Grate This fi replace is designed to be used with the grate sup- plied with this unit or one approved by HHT.
  • Page 9: Glass Doors

    WARNING! Risk of Fire or Asphyxiation! • DO NOT install unvented gas logs. • Damper must be locked open. • Gas fl ame may generate fumes. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 FULLY OPEN CORRECT FULLY CLOSED CORRECT Figure 2.2...
  • Page 10: Wood Fuel

    Wet, unseasoned wood requires energy to evaporate the water instead of heating your home, and • Evaporating moisture cools your chimney, accelerating formation of creosote. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 Seasoned Wood • Cut logs to size •...
  • Page 11: Maintainance And Service

    Round Termination Cap Figure 3.1 Chimney & Termination Cap Cleaning Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 B. Chimney Inspection/Cleaning Frequency: At least twice a year during heating season or as recommended by a certifi ed chimney sweep By: Certifi...
  • Page 12: Check Firebox Refractory

    • Light deposits Use household glass cleaner • Heavy deposits Use wood ash on damp cloth or, Use commercial fi replace glass cleaner (consult with your dealer) Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08...
  • Page 13: Troubleshooting Guide

    Excessive smoke or spillage Burns too slowly Smolders, sizzles Fire burns too fast Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 Possible Cause Solution Not enough kindling/paper or no Use dry kindling, more paper. Arrange kindling &...
  • Page 14: Getting Started

    (Section 7) Protective metal hearth strip(s) (Section 7) Figure 5.1 Typical Fireplace System Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 NOTICE: • Illustrations and photos reflect typical installations and are for design purposes only. •...
  • Page 15: Design And Installation Considerations

    Mechanical exhausting devices • Improper location of the chimney Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 D. Negative Pressure WARNING! Risk of Asphyxiation! Negative pressure can cause spillage of combustion fumes and soot. Fire must draft properly for safe operation.
  • Page 16: Locating Fireplace & Chimney

    • Not the highest point of the roof • Wind loading possible Windward Figure 5.2 Recommended Chimney Locations Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 Recommended Location: • Above peak • Inside heated space Marginal Location: Marginal Location: •...
  • Page 17: Tools And Supplies Needed

    Chimney System (required, sold separately) • Termination Cap (required, sold separately) Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 H. Inspect Fireplace and Components WARNING! Risk of Fire and/or Explosion! Damaged parts could impair safe operation. DO NOT install dam- aged, incomplete or substitute components.
  • Page 18: Framing & Clearances

    HEARTH EXTENSION (shaded) 64 in. BAY-40 (1626 mm) Figure 6.1 Fireplace Locations Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 62 in. (1575 mm) 16 in. (406 mm) 56 in. (1422 mm) 26 in. (660 mm)
  • Page 19: Clearances

    Ceiling Firestop 1/2 in. (13 mm) to back of appliance Figure 6.2 Air Space Clearances Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 Storm Collar Roof Flashing 2 in. (51 mm) min. air space clearance...
  • Page 20: Sidewalls/Surrounds

    Framing across the top of fi replace must be above top standoffs. 2 in. (51 mm) minimum air space clearance to enclosure BAY-40 Figure 6.4 Framing the Fireplace Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 36 in. [914 mm] [914 mm] (fireplace opening) (fireplace opening 40 in.
  • Page 21: Installation Of Fireplace

    Check fi replace opening for square to ensure proper fi t of glass doors. Measure diagonals of fi replace opening to make sure they are equal. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 1 in. (25 mm) overlap Metal strips 2 in.
  • Page 22 Figure 7.4 Outside Combustion Air Placement Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 Garage or Attic space Outlet placed...
  • Page 23: Install Outside Air Kit

    Figure 7.5 Typical Outside Air Installation (BAY-40 will be in- stalled from the bottom of the fi replace) Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 AK17 Installation (BAY-40) • Remove the cover plate from the bottom of the fi replace and replace it with outside air plate assembly using existing screws.
  • Page 24: Chimney Assembly

    Lock chimney sections together firmly to resist movement Figure 8.1 Typical Chimney System - Guidelines for Chimney System Installation Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 Termination Cap Additional support for tall chimneys Storm Collar...
  • Page 25: Chimney Requirements

    SL1118 SL1136 SL1148 * Dimensions refl ect effective height. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 Determine the chimney components needed to complete your particular installation: • Measure the total vertical height of the fireplace installation from the base of the fi...
  • Page 26: Using Offsets/Returns

    Proper assembly of air cooled chimney parts results in an overlap of chimney joints of 1-1/4 in. (32 mm). Effective length is built into this table. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 Example: Your “A”...
  • Page 27: Assemble Chimney Sections

    Vertical straight runs of chimney must be supported every 35 ft (10.7 m). D. Install Chimney Air Kit Follow instructions provided with this accessory. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 Figure 8.4 Assembling Chimney Sections...
  • Page 28: Install Ceiling Firestops

    fi restop opening and chimney pipe except where they enter the attic or leave the warm air envelope of the home (use 600° F sealant). Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 ROOM ABOVE (non-insulated ceiling) Ceilng firestop from...
  • Page 29: Install Attic Insulation Shield

    • Maintain specifi ed air spaces around chimney. • Check instructions and local codes for further details. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 Bend remaining tabs to rest against pipe to prevent insulation Bend inward from falling in.
  • Page 30: Cut Out Hole In Roof

    Caulk the fl ashing plate and roof junction as well as the vertical seam on the fl ashing. All nail heads must be caulked with a roofi ng sealant. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 Figure 8.9 Ceiling/Attic Construction...
  • Page 31: Chimney Termination Requirements

    152 mm/508 mm 20 in. and over Figure 8.10 Multiple Chimney Locations Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 Chimney must extend 2 ft (.6 m) above any portion of the roof or adjacent structures within 10 ft (3 m) of the chimney Chimney must extend 2 ft (.6 m)
  • Page 32: Chase Installations

    Chimney Figure 9.1 Chase Assembly Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 Gas line holes and other openings should be caulked with high temperature caulk or stuffed with unfaced fi berglass insulation. If the fi replace is being installed on a cement...
  • Page 33: Install Fireplace & Chimney

    • Caulk all seams to prevent leaks. • Refer to Figure 9.4. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 2 in. (51 mm) Collar Slope Downward on Chase Top (1/4 in. per foot minimum) .018 (26 ga) min.
  • Page 34: Install Termination Cap

    Termination cap pipe and chimney section must be snapped together to maintain an overlap of 1-1/2 in. (38 mm). Figure 9.4 Installing a TR11 Round Termination Cap Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 • TR11T Round Telescoping Termination Cap Assemble...
  • Page 35 Termination cap pipe and chimney section must overlap 1-1/2 in. (38 mm) Figure 9.7 Installing a TCT1175 Terra Cotta Cap Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 Place waterproof sealer under each flange of the termina-...
  • Page 36: Shrouds

    Width Min. Base Dim. Figure 10.2 Open Top Shroud Dimensions Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 Ø 17 1/2 in. (444.5 mm) Round Hole to fit over cap Figure 10.1 Radiation Shield •...
  • Page 37 Radiation Shield Termination 3 in. (76 mm) Radiation Shield Height Figure 10.4 Roofed Style Shroud Dimensions Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 3 in. (76 mm) Min. Opening Height Min. Base Dim Minimum Opening...
  • Page 38: Finishing

    Ceramic Tile Armstrong™ Privacy Guard Plus Marble Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 C. Hearth Extension WARNING! Risk of fi re! High temperatures, sparks, embers or other burning material falling from the fi replace may ignite fl...
  • Page 39 1/2 in. Micore Hearth Ext or equivalent insulation (see Table 11.2) Figure 11.1 Hearth Extension Dimensions Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 (1575 mm) 16 in. (406 mm) 56 in. (1422 mm) 26 in.
  • Page 40: Finishing Material

    1/2 in. Micore or equivilent insulation Figure 11.3 Decorative Facing Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 Figure 11.2 Noncombustible Materials Zone Flat 2 x 4 stud wall 2 x 4 header, flush with...
  • Page 41: Combustible Mantel

    [305 mm] Figure 11.5 Mantel Leg or Wall Projections (acceptable on both sides of opening) Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 12 in. (305 mm) Figure 11.4 Clearances to Mantels or other Combustibles above Fireplace 36 in.
  • Page 42: Accessories

    4 in. (102 mm) Figure 12.1 Gas Line Installation Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 B. Wood Burning Inserts WARNING! Risk of Fire! Improper installation of wood in- serts may cause fi replace or chimney system to overheat.
  • Page 43: Reference Materials

    Reference Materials A. Fireplace Dimensions " 42" 36" 40" FRONT VIEW - BAY-40 END VIEW - BAY-40 Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 42" 22½" 36" 5¾" ½" 40" FRONT VIEW - PIER-40 KNOCKOUT "...
  • Page 44: Optional Components

    HX4 Hearth Extension 1/2 in. (13 mm) See your Heat & Glo dealer for a complete listing of optional components. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 16 in. (406 mm) 20 in. (508 mm)
  • Page 45: Chimney Components

    5-1/4 in. (133 mm) 13 in. (330 mm) CAK5A Chimney Air Kit Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 11 in. (279 mm) Catalog # A = Actual Length B = Effective Length (length of 14 in.
  • Page 46 (330 mm) JB577 Chimney Joint Band 13 in. (330 mm) CB576 Chimney Joint Band 10 3/4 in. CT-11A Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 Outside Diameter 13 in. (330 mm) 2 in. (51 mm) 26 in.
  • Page 47 (432 mm) 9-3/8 in. (238 mm) 9-1/4 in. (235 mm) TCT1175 - Terra Cotta Cap Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 72 in. (1829 mm) 13-3/8 in. (340 mm) CT56 Chase Top LDS33/LDS46 Decorative Shroud...
  • Page 48: Service Parts

    D. Service Parts Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08...
  • Page 49 D. Service Parts (continued) Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08...
  • Page 50 This page intentionally left blank. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08...
  • Page 51 This page intentionally left blank. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08...
  • Page 52: Contact Information

    6748942, 6769426, 6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending. Heat & Glo • BAY-40, PIER-40 • 34977 • Rev W • 11/08 – NOTES – CAUTION DO NOT DISCARD THIS MANUAL •...

This manual is also suitable for:

Bay-40

Table of Contents