Fireplace
Maintenance
IMPORTANT
Type of
Maintenance
Frequency
Replacing
Once annually,
Old Ember
during the
Material
annual check-up
Cleaning
Once annually
Burner
& Controls
Cleaning
Periodically
Flame Sensor
Rod (IPI)
System
Checking
Periodically
Flame
Patterns,
Flame Height
Checking
Before initial use
Vent System
and at least
annually thereafter,
more frequently
if possible
Cleaning
As necessary
Although the frequency fireplace servicing and
maintenance will depend on use and the type of
installation, you should have a qualified service technician
perform an appliance check-up at the beginning of each
heating season. See the table below for specific
guidelines regarding each fireplace maintenance task.
TURN OFF THE GAS BEFORE SERVICING

YOUR FIREPLACE.

Fireplace Maintenance Task To
By
Qualified
Brush away loose ember material near
Service
the burner. Replace old ember
Technician
material with new dime-size and -shape
pieces of Golden Ember (GE-93) and
Glowing Ember (050-721). New ember
material should be placed alternately on
top of the burner—a layer of Golden
Ember, a layer of Glowing Ember,
and so on. Save the remaining ember
material and repeat this procedure at
your next servicing.
Qualified
Brush or vacuum the control
Service
compartment, fireplace logs, and
Technician
burner areas surrounding the logs.
Qualified
Make a visual check of the straight flame
Service
sensor rod. Use emery cloth to carefully
Technician
remove any existing film or white deposits.
Qualified
Make a visual check of your fireplace's
Service
flame patterns. Make sure the flames
Technician/
are steady—not lifting or floating. See
Owner
the picture in Figure 14. The flame
sensor or thermopile/thermocouple
tips should be covered with flame.
Qualified
Inspect the external vent cap on a
Service
regular basis to ensure that no debris is
Technician/
interfering with the flow of air. Inspect
Owner
entire vent system for proper function.
Homeowner Remove and clean glass after the first 3-4
hours of use. After the initial cleaning, clean
as necessary, particularly after adding new
ember (flame colorant) material. Film deposits
on inside of glass door should be cleaned
off using a household glass cleaner. NOTE:
DO NOT handle or attempt to clean door
when it's hot. DO NOT use abrasive cleaners.
MAKE SURE THE FLAMES
ARE STEADY—NOT LIFTING
OR FLOATING.
Figure 14.
Burner Flame Patterns