V External View (2)
Paper Return Plate
Figure 4-24. ASF Unit Removal (2)
DISASSEMBLY AND ASSEMBLY
Rear View
Torsion Spring 29.1
Rear View
Hinge
Disassembly
3.
Remove Torsion Spring 29.1 from ASF Frame and Paper Return Plate by
using tweezers.
4.
Remove the hinge of Paper Return Plate by using tweezers, and then remove
Paper Return Plate.
Confirm that Paper Return Plate operates smoothly.
A D J U S T M E N T
When having removed or replaced ASF Unit, implement the
R E Q U I R E D
following adjustment. (Refer to Chapter 5 "ADJUSTMENT")