EPSON Stylus CX1500/ME100

4.3.5 Scanner Unit

V External View (1)
Double-sided tapes
J8
J6
Support Band
Hook
Housing Upper
Scanner Unit
2
Figure 4-7. Scanner Unit Removal
DISASSEMBLY AND ASSEMBLY
Approx. 60º
1
Disassembly
V Part/Unit that should be removed before removing Scanner Unit.
Document Cover / Panel Unit / Panel Housing
V Removal procedure
1.
Disconnect the following Connector Cables and FFC from the connectors of
Main Board.
• J6: Scanner Motor Connector Cable
• J8: Scanner Carriage FFC
The Scanner Carriage FFC is fastened with the double-sided tape, so
C A U T I O N
be careful not to damage FFC when removing it.
2.
Rotate lower side of Support Band sideways by 90º, and then release Support
Band hook (x1,
) from the notch in Housing Upper.
3.
Lift the Scanner Unit to the position as shown in the figure (approx. 60º), and
while lifting Scanner Motor Connector Cable and Scanner Carriage FFC by
hand, remove Scanner Unit using the steps shown in the figure.
T
Align the positioning hole (x1,
dowel (x1,
) of Housing Middle.
Positioning hole
Figure 4-8. Installation of Scanner Unit
T
Do not pinch Scanner Motor Connector Cable and Scanner
Carriage FFC between the Scanner Unit and Housing Upper.
Revision A
) of Scanner Unit with the
Dowel