Status Commands - Comtech EF Data UT-4505 Installation And Operation Manual

Ut-4500 series
Hide thumbs Also See for UT-4505:
Table of Contents

Advertisement

UT4500 Series Up Converter
Remote Control
5.6.3.3 B
M
ACKUP
This command allows the user to force a backup condition for maintenance and test
purposes. This command must be sent to the converter designated as the backup
converter (i.e., "BU"). When activated this command forces the backup converter to
assume the state of the specified chain converter and forces the chain converter offline.
Command
Initiate a Backup:
Confirmation:
Retrieve Backup
Status:
Confirmation:
5.6.4 S
C
TATUS
Status commands retrieve configuration, maintenance and alarm status in summary form.
5.6.4.1 C
ONFIGURATION
Command
Configuration Status:
Confirmation:
Note: If Redundancy OFF xx_yy_z = OFF, else if Redundancy ON and converter selected as
backup controller xx_yy_z = BU_yy where yy is the number of converters in the chain
(i.e. 01 to 12), else if Redundancy ON and converter selected as a chain unit xx is the
converter number (01 to 12), and z = A if Auto Mode or M if Manual Mode.
ODE
Details
<DEV/FBU_xx_y'cr'
>DEV/FBU_xx_y'cr''lf']
Where: xx = 01 to 12, converter number
y = 'F' to force a backup 'N' to remove a backup
<DEV/FBU_'cr'
>DEV/FBU_xx_zzzzz'cr''lf']
Where: xx = 01 to 12, converter number. If zzzzz = NONE, converter
number is not displayed.
zzzzz = 'NONE' if no backup active
= 'ACTIVE' if an automatic backup has occurred
= 'FORCED' if a forced backup is active
OMMANDS
S
TATUS
Details
<DEV/RCS_'cr'
>DEV/RCS_'cr'
FRE_xxxxx.xxx'cr'
ATT_yy.yy'cr'
TX_nnn'cr'
ONL_nnn'cr'
RED_xx_yy_z'cr'
CLD_nnn'cr'
AFR_nnn'cr'
EXT_xxx'cr''lf']
Frequency
Attenuator
Transmitter - ON/OFF/COLD
Online - ON/OFF
See Note
Cold Start - ON/OFF
Auto Flt Recovery-ON/OFF
Ext. Ref. - YES/NO