Error Response; End Of Message - Comtech EF Data UT-4505 Installation And Operation Manual

Ut-4500 series
Hide thumbs Also See for UT-4505:
Table of Contents

Advertisement

UT4500 Series Up Converter
Remote Control
5.5.5 E
R
RROR
If a converter cannot execute a Command or detects a protocol violation, an error
response is generated. An error is flagged by changing the "/" command designator in the
response to a "?". Following the "?" error symbol are two characters which are unique
error symbols useful for computer analysis. The two error symbols are followed by a text
string explaining the error for the convenience of a human operator. For this document
ER is used for the generic case examples response.
Example:
5.5.6 E
O
M
ND
F
End of message strings were devised in such a way that an orderly screen presentation
would result when converters are controlled by simple ASCII terminals.
5.5.6.1 C
OMMAND
The end of message for a command is a carriage return. For this document 'cr' is used for
the carriage return.
Example:
5.5.6.2 R
ESPONSE
End of message for a response is a carriage return, line feed and a bracket: 'cr''lf'].
Example:
ESPONSE
>DEV?COM ER Error Message 'cr''lf']
ESSAGE
E
NDING
<DEV/COM_'cr'
E
NDING
>DEV/COM_'cr''lf']
62
MN/UT4500.IOM
Revision 2

Hide quick links:

Advertisement

Table of Contents
loading