Comtech EF Data UT-4505 Installation And Operation Manual page 27

Ut-4500 series
Hide thumbs Also See for UT-4505:
Table of Contents

Advertisement

UT4500 Series Up Converter
Introduction
Characteristic
Phase Noise
100 Hz
1 KHz
10 KHz
100 KHz
1 MHz
Remote Control (Rear Panel)
Indicators (Front Panel)
Power On
Mute
Remote
Reference
Stored Fault
Fault
Test Points (Front Panel)
RF Sample
IF Sample
Optional L.O. Sample
Power
Voltage
Frequency
Dissipation
Environmental
Temperature
Altitude
Humidity
Physical
Width
Height
Depth
Weight
MTBF
Summary Alarm
Relay Closure
Specification
Limit (dBc/Hz)
-69
-79
-89
-99
-109
Comm Port EIA-485 or EIA-232
Green LED
Yellow LED
Yellow LED
Yellow LED
Red LED
Red LED
SMA, -20 dBc Nominal
BNC, -20 dBc Nominal
90 to 250 Vac Autoranging, optional –48 Vdc
47 to 63 Hz
60 Watts
0 to 50° C (32 to 122° F)
10,000 Feet MSL
0 to 95 % Relative
19 Inches
(48.30 cm)
1.75 Inches
(4.45 cm)
22 Inches
(55.90 cm)
15 Pounds
(7.00 kg)
49,740 hrs.
(calculated)
>100,000 hrs.
(field experience)
Form C
9
MN/UT4500.IOM
Revision 2
Typical (dBc/Hz)
-72
-82
-92
-102
-112

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents